DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
26
4-2. Description of each operation mode
This power supply can be used in the following operation modes.
The control mode is switched on the front panel or using commands via the SERIAL communication
port.
(For instructions to make the settings, see the section about MODE on “5-1-4 MENU”)
Table 4-3: Each oper
Operation mode
Overview
LOCAL
This is controlled using the front panel.
USER
The control is made from USER I/O PORT.
HOST
The control is made via SERIAL communication (RS-232C, RS-485).
HOST+
Only switching on or off the output is controlled from the I/O port.
Controls for the other than above are performed via SERIAL
communication (RS-232C, RS-485).
The parameters in each operation mode can be changed with the interface shown below.
Table 4-4: Interfaces operational in each operation mode
Present operation mode
LOCAL
USER
HOST
HOST+
Operation of switching
on or off the output
Front panel
USER I/O PORT
SERIAL
communication port
USER I/O PORT
Change of operation
mode
Front panel
SERIAL
communication port
Front panel
SERIAL
communication port
Front panel
SERIAL
communication port
Front panel
SERIAL
communication port
Change of power control
mode
Front panel
USER I/O PORT
SERIAL
communication port
SERIAL
communication port
Oscillation frequency
Front panel
Front panel
SERIAL
communication port
SERIAL
communication port
Inversion pulse width
Front panel
Front panel
SERIAL
communication port
SERIAL
communication port
Oscillation mode
Front panel
USER I/O PORT
SERIAL
communication port
SERIAL
communication port
PULSE PARAM SEL
Front panel
USER I/O PORT
SERIAL
communication port
SERIAL
communication port
Reset signal
Front panel
USER I/O PORT
SERIAL
communication port
SERIAL
communication port
Interlock
USER I/O PORT
USER I/O PORT
USER I/O PORT
USER I/O PORT
Setup for optical
synchronization
Front panel
Front panel
SERIAL
communication port
SERIAL
communication port
Other parameters
Front panel
Front panel
SERIAL
communication port
SERIAL
communication port
The interlock for the 37-34 pin of USER IO PORT is effective in every operation mode.
Learn how to release the accessory connector etc.
4-2-1. Description of LOCAL mode function
Switching to the LOCAL settings enables one to set output set values on the front panel and to
operate ON/OFF of Output.
4-2-2. Description of USER mode function
Switching to the USER setting enables one to connect the power supply with external control devices,
such as a PLC, to exchange necessary information from USER IO PORT.