DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
47
* Example of changes on the main screen
In the menu screen: the hierarchy in the menu is decided.
In the parameter setting, the set parameter is decided.
・
About FNC button
Pressing together with the FNC button switches to the functions below the button.
ESC
ARC
ENT
RESET
MENU
ERROR
FNC
・
ARC COUNT check “FNC+ESC”
Pressing the FNC and ESC (ARC) buttons together enables one to check the number of times
that hard arcs occur.
The maximum countable number of times is 99,999,999. Pressing the ESC button returns to the
main screen.
When the breaker is shut off, the counts are reset.
・
ERROR log check “FNC+MENU”
Pressing the FNC and MENU (ERROR) buttons together enables one to check the log of ERROR
occurrence.
Pressing the ESC button returns to the main screen.
・
ERROR RESET “FNC+ENT”
Pressing the FNC and ENT (RESET) buttons together resets ERROR. (*Enabled only in the
LOCAL mode)
In addition, when it is reset while the ARC COUNT number is displayed, the number of times that
hard arcs are detected is reset.
ENT button
The changes are
accepted.
◀
appears.
Select the item to
be changed by
◀▶
button.
ENT button
The setting item to
be changed blinks.
Make changes to the
setting by
◀▶
▲▼
button.
ENT button
The display "
◀
" is disappeared and the state possible to output
comes up.
The output is disabled while the "
◀
" is being displayed.
button
▲▼