DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
49
MODE
:
this is used to select a output control mode.
SEL: this is used to select a output control mode.
LOCK: With this option, it can be set that the output control mode is selected only on the
front panel.
SEL: this is used to select a output control mode.
POWER:
the output is produced by the power control.
VOLTAGE: the output is produced by the voltage control.
CURRENT: the output is produced by the current control.
LOCK: With this option, it can be set that the output control mode is selected only on the front
panel.
NO:
the output control mode is not locked.
YES: the selection of a control mode from USER IO PORT is not accepted so that it can be
changed only on the front panel.
In the SERIAL communication control mode, the SERIAL communication is followed
regardless of what is selected.
In the LOCK mode, the SET display in the main screen shows < and >.
・
UNIT: this is used to select the number of DC power supplies in use.
The setup is carried out in the M/S.
※
This setting is available only to the master device.
The number of connected power supply units is specified.
LIMT: this is used to decide the limits of each output value.
POWR: this enables one to change the limit value of the output power.
VOLT: this enables one to change the limit value of the output voltage.
CRNT: this enables one to change the limit value of the output current.
When reaching the limit value, further output is not carried out, and the item standing at the limit
is blinked in the front face.