background image

                                                                                                                                                                   

VER : 

A_8

    update : 

2020.08.27

 

 
                                                                              AC-DC Switching Power Supply 

                                                                                                                     

AQF600 SERIES 

                                                                                                                 

600  Watts

 

 

http://www.archcorp.com.tw

                                                                                                                                         

TEL: +886-2-26989508  FAX: +886-2-26981319                                                                                        -1- 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL SPECIFICATIONS 

All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.

 

Model 

No. 

AQF600-12S AQF600-24S AQF600-48S AQF600-54S 

Max Output Wattage  (Convection)   (W) 

540W 

600W 

600W 

600W 

Input 

Voltage 

90-264 VAC or 120-370 VDC 

Frequency (Hz) 

47-63 Hz 

Current (Full load) 

< 8.0 A max. (115 VAC) / < 3.5 A max. (230 VAC) 

Inrush Current (<2ms) 

< 15 A max. (115 VAC) / < 30 A max. (230 VAC) 

Leakage Current 

< 3.5 mA max.(240VAC 63Hz) 

Power Factor 

PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load 

Output 

Voltage (V.DC.) 

12V 

24V 

48V 

54V 

Trim ±5% 

Voltage Accuracy 

±2% 

Current (Convection) (A) max 

45 

25 

12.5 

11.1 

Line Regulation (LL-HL) (typ.) 

±1% 

Load Regulation (5-100%) (typ.) 

±1% 

Minimum Load 

1% 

Maximum Capacitive Load 

60,000 uF 

50,000 uF 

20,000 uF 

10,000 uF 

Ripple & Noise (max.) 

< 1% Vout 

Efficiency (typ.) 

90% 

92% 

92% 

93% 

Hold-up Time 

12 ms min. 

Protection 

Over Power Protection 

Auto recovery 

Over Voltage Protection 

Auto recovery 

Over Temperature 

Auto recovery 

Short Circuit Protection 

Latch off 

Isolation 

Input-Output (V.AC) 

3000VAC or 4242VDC 

Input-FG    (V.AC) 

1500V 

Output-FG 

  .

(V.AC) 500V 

Function 

5V Stand by (18CFM FAN) 

5VSB: [email protected] ; Tolerance 

10% , Ripple & Noise: 100m Vp-p (max.) 

DC OK Signal (Power Good) 

Turn ON: 3.7~5.7V ; Turn OFF: 0~1V 

Remote Control 

+RC / -RC: Power ON=open ; Power OFF=short 

Current Share 

CN4:CS, +V, -V are connected mutually in parallel. 

Environment 

Operating Temperature 

-25°C…+70°C (with derating) 

Storage Temperature 

-25°C…+85°C 

Temperature Coefficient 

±0.03%/°C ( 0~50°C ) 

Humidity 95% 

RH 

MTBF 

>100,000 h @ 25°C (MIL-HDBK-217F) 

Vibration 

10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. 

 

KEY FEATURES 

  Universal Input: 90-264 VAC 

  With P.F.C. Function, PF>0.95 

  Remote ON/OFF Function 

 Current 

Share 

Function 

  Power Good Function 

  High Efficiency up to 90~93% 

  Protections: Over Load / Over Voltage /   

                    .

Over Temperature / Short Circuit 

  High Power Density 

  RoHS Compliant Design 

  3-Year Product Warranty      

Содержание AQF600 Series

Страница 1: ...Ripple Noise max 1 Vout Efficiency typ 90 92 92 93 Hold up Time 12 ms min Protection Over Power Protection Auto recovery Over Voltage Protection Auto recovery Over Temperature Auto recovery Short Circuit Protection Latch off Isolation Input Output V AC 3000VAC or 4242VDC Input FG V AC 1500V Output FG V AC 500V Function 5V Stand by 18CFM FAN 5VSB 5V 0 6A Tolerance 10 Ripple Noise 100m Vp p max DC O...

Страница 2: ...ions L x W x H 9 0 x 4 13 x 1 72 Inches 228 5 x 105 0 x 44 0 mm Tolerance 0 5 mm Weight 1024 50 g Cooling Integral fan Safety Agency Approvals CE UL60950 1 EMC EMI Conducted Radiated Emission EN 55032 class B Radiated Class A EMS Noise Immunity EN 55024 Surge 1KV L N 2KV L N FG NOTE 1 Ripple Noise are measured at 20MHz of bandwidth with 0 1uF 47uF parallel capacitor 2 Strongly recommend to conduct...

Страница 3: ...2 0mm Customer is advised to screw into the threads no more than 2 0mm T 2 0mm Chassis of AQF600 Series Brands PIN Single Terminal 1 AC IN 2 4 DC OUT DINKLE DT 49 B01W 06 5 7 DC OUT Connector Pin CN4 Brands Cherng Weei JST PIN Single Mating Housing Terminal Mating Housing Terminal C1 S PHD H20 2X4P PHD T20 PHDR 08VS SPHD 001T P0 5 C2 S C3 CS C4 GND C5 GND C6 RC C7 PG C8 5V AUX Torque 3 0 5 Kgf cm ...

Страница 4: ... by voltage output ground 4 5 5 5V referenced to pin C4 or C5 GND The maximum load current is 0 6A FUNCTION MANUAL APPLICATION NOTE 1 DC OK Signal Between DC OK pinC5 and GND pinC6 Output Status 3 7 5 7V ON 0 1V OFF 2 Remote Control It can be turned ON OFF by using the Remote Control function Between RC pinC3 and RC pinC4 Output Status SW ON Short OFF SW OFF Open ON 3 Current Share 1 Difference in...

Страница 5: ... 26981319 5 4 1 1 Redundancy sing 1 more AQF600 as the redundant unit 5 1 N Redundancy Using more AQF600 as the redundant units to increase the reliability We reserve the right to make alterations in the product materials and specifications without prior notification and consent to improve reliability function or design or otherwise ...

Отзывы: