DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
55
RMP2
:
this changes the rise time at the start of the output.
With this ramp function, the rise time until the command value of the output can be
adjusted.
USE:
Set ON/OFF of the ramp function.
TIME: Set the rise time from the start of ramping to the command value.
STRT: Set the initial value for the start of ramping.
USE
:
set ON/OFF of the ramp function.
DISBL: This switches off the ramp function.
ENABL: This switches on the ramp function.
TIME
:
set the rise time from the start of ramping to the command value.
The rise time from START to the command value can be set.
The settable range is 0.05 to 600 sec in steps of 0.01 sec.
Ramp time functions 1 and 2 cannot be used together.
If one ramp function is enabled, the other ramp function will be disabled.
RTC: The current time can be viewed and set.
The current time can be viewed and set.
No backup is taken by the battery and therefore the set time is reset a few hours after the
breaker is turned off.
If backups need to be taken by the battery, contact the store of purchase.
SERV: this enables one to check the hardware configuration.
HARD: the power (M/N) is displayed.
CHCK
:
the checksum value of Power parameter is displayed.
HARD
:
the power (M/N) is displayed.
CHCK
:
The checksum value of power parameter is displayed.
The checksum value of the current parameter is displayed.
CAUTION