DIAGNOSTICS
AIR CONDITIONING SYSTEM
DI-699
853
Author:
Date:
2001 SIENNA (RM787U)
Rear A/C
Symptom
Suspect Area
See page
Whole functions of the rear A/C system does not operate
1. IG power source circuit
2. A/C control assembly
Air Flow Control: No blower operation (for rear cooling)
1. IG power source circuit
2. Rear CLR relay circuit
3. Rear blower motor circuit
4. A/C control assembly
Air Flow Control: No blower operation (for rear heater)
1. IG power source circuit
2. Rear heater relay circuit
3. Rear blower motor circuit
4. A/C control assembly
Air Flow Control: No blower control (for rear cooling)
1. Rear blower motor circuit
2. A/C control assembly
3. Solar sensor circuit
Air Flow Control: No blower control (for rear heater)
1. Rear blower motor circuit
2. A/C control assembly
3. Solar sensor circuit
Air Flow Control: Insufficient air flow (for rear cooling)
1. Rear blower motor circuit
Air Flow Control: Insufficient air flow (for rear heater)
1. Rear blower motor circuit
Temperature Control: No cool air comes out
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Expansion valve
5. Evaporator
6. Compressor circuit
7. Rear air mix damper position sensor circuit
8. Rear air mix damper control servomotor circuit
9. Rear room temp. sensor circuit
10.A/C control assembly
Temperature Control: No warm air comes out
1. Rear air mix damper position sensor circuit
2. Rear air mix damper control servomotor circuit
3. Rear room temp. sensor circuit
4. Rear air intake temp. sensor circuit
5. A/C control assembly
Temperature Control: Output air is warmer or cooler that the set
temperature or response is slow
1. Refrigerant volume
2. Drive belt tension
3. Refrigeration system inspection with manifold gauge set
4. Cooling fan system
5. Solar sensor circuit
6. Rear room temp. sensor circuit
7. Rear air intake temp. sensor circuit
8. Rear air mix damper position sensor circuit
9. Rear air mix damper control servomotor circuit
10.Condenser
11.Evaporator
12.Heater radiator
13.Expansion valve
14.A/C control assembly
Temperature Control: No temperature control (only Max. cool or
Max. warm)
1. Rear room temp. sensor circuit
2. Rear air mix damper position sensor circuit
3. Rear air mix damper control servomotor circuit
4. A/C control assembly
Содержание RM787U
Страница 736: ...DIAGNOSTICS POWER SLIDE DOOR CONTROL SYSTEM DI 505 659 Author Date 2001 SIENNA RM787U f Repeat the step d and e...
Страница 1619: ...BE0EX 03 I03187 Power Outlet BODY ELECTRICAL POWER OUTLET BE 13 1531 Author Date 2001 SIENNA RM787U POWER OUTLET LOCATION...
Страница 1883: ...AC0951 Stator AIR CONDITIONING COMPRESSOR AND MAGNETIC CLUTCH AC 65 1906 Author Date 2001 SIENNA RM787U c Remove the stator...