I21009
To ”RECIRCULATION”
4
5
(+)
(-)
4
5
(+)
(-)
To ”FRESH”
-
DIAGNOSTICS
AIR CONDITIONING SYSTEM
DI-741
895
Author:
Date:
2001 SIENNA (RM787U)
2
Check air inlet damper control servomotor.
PREPARATION:
Remove the air inlet damper control servomotor (See page
CHECK:
Connect positive (+) lead to terminal 5 and negative (-) lead to
terminal 4.
OK:
The lever moves smoothly to ”RECIRCULATION”
position.
CHECK:
Connect positive (+) lead to terminal 4 and negative (-) lead to
terminal 5.
OK:
The lever moves smoothly to ”FRESH” position.
NG
Replace air inlet damper control servomotor as-
sembly.
OK
3
Check harness and connector between A/C control assembly and air inlet damp-
er control servomotor (See page
).
NG
Repair or replace harness or connector.
OK
Check and replace A/C control assembly.