I01702
Relay Side
e-6-2-G
I21513
Check continuity
between terminal 3 and 4.
Continuity
No continuity
3
4
5
No continuity
Continuity
N21368
2
1
BE-40
-
BODY ELECTRICAL
WIPER AND WASHER SYSTEM
1558
Author:
Date:
2001 SIENNA (RM787U)
10.
INSPECT REAR WIPER RELAY CONTINUITY
Terminal
Specified condition
3 - 4
No continuity
4 - 5
Continuity
If continuity is not as specified, replace the relay.
11.
INSPECT REAR WIPER RELAY OPERATION
(a)
Connect the positive (+) lead from the battery to terminal
3 and the negative (-) lead to terminal 4.
(b)
Check continuity between terminals.
Terminal
Specified condition
3 - 4
Continuity
4 - 5
No continuity
If continuity is not as specified, replace the relay.
12.
INSPECT REAR WIPER RELAY INTERMITTENT OP-
ERATION
(a)
Connect the positive (+) lead from the battery to terminal
3 and the negative (-) lead to terminal 2.
(b)
Check continuity between terminal 3 and 4 is as illus-
trated.
If continuity is not as specified, replace the relay.
13.
INSPECT WASHER MOTOR OPERATION
Connect the positive (+) lead from the battery to terminal 2 and
the negative (-) lead to terminal 1, check that the motor oper-
ates.
NOTICE:
These tests must be performed quickly (within 20 seconds)
to prevent the coil from burning out.
If operation is not as specified, replace the motor.
Содержание RM787U
Страница 736: ...DIAGNOSTICS POWER SLIDE DOOR CONTROL SYSTEM DI 505 659 Author Date 2001 SIENNA RM787U f Repeat the step d and e...
Страница 1619: ...BE0EX 03 I03187 Power Outlet BODY ELECTRICAL POWER OUTLET BE 13 1531 Author Date 2001 SIENNA RM787U POWER OUTLET LOCATION...
Страница 1883: ...AC0951 Stator AIR CONDITIONING COMPRESSOR AND MAGNETIC CLUTCH AC 65 1906 Author Date 2001 SIENNA RM787U c Remove the stator...