SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
849
Note:
After Auto-Tuning is complete and you set the drive to Drive Mode, operate the motor in these conditions:
•
Make sure that you connect all wiring between the drive and motor
•
Make sure that a mechanical brake on the motor shaft is not locked
•
Keep the motor-load ratio at 30%
•
Hold constant speed for longer than 1 second at a minimum of 30% of the speed set in
E1-06 [Base Frequency]
(the default setting is
the same as the maximum frequency).
■
T1-13 No-load Voltage
No.
(Hex.)
Name
Description
Default
(Range)
T1-13
(0BDC)
No-load Voltage
Sets the no-load voltage of the motor. If no-load voltage is necessary at rated speed for the motor
test report, set the voltage in this parameter. If the motor test report is not available, do not change
this parameter.
90% of T1-03
(400 V Class: 0.0 - 510.0
V)
◆
T2: PM MOTOR
T2 parameters
set the Auto-Tuning input data for PM motor tuning.
Note:
The drive automatically sets these PM motor parameters:
•
E1-xx [E1: V/F PARAMETER MOTOR 1]
•
E5-xx [E5: PM MOTOR SETTINGS]
•
F1-xx [F1: ENCODER] (CLV only)
■
T2-01 PM AutoTune Mode Select
No.
(Hex.)
Name
Description
Default
(Range)
T2-01
(0750)
PM AutoTune Mode Select
Sets the type of Auto-Tuning for PM motors.
0
(Determined by A1-02)
Note:
For specialized motors, Rotational (Ld, Lq, R, back-EMF) tuning is recommended. Rotational Auto-Tuning rotates the motor to measure
the actual induction voltage constants for more accurate control than Stationary Auto-Tuning.
0 : PM Motor Parameter Settings
1 : PM Static Full AutoTune
2 : PM Static R Autotune
3 : Encoder Offset Autotune
4 : PM Rotary Autotune
■
T2-02 PMMot Code Selection
No.
(Hex.)
Name
Description
Default
(Range)
T2-02
(0751)
PMMot Code Selection
Sets the PM motor code for drives operating SMRA, SSR1, or SST4-series Yaskawa PM motors.
Determined by A1-02 and
o2-04
(0000 - FFFF)
Enter the motor code in
T2-02
to automatically set parameters
T2-03
to
T2-14
. When you are operating a
specialized motor or a non-Yaskawa motor designed, set
T2-02
=
FFFF
and enter the data from the motor
nameplate or the motor test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor
codes.
■
T2-03 PMMot Motor Type
No.
(Hex.)
Name
Description
Default
(Range)
T2-03
(0752)
PMMot Motor Type
Sets the type of PM motor the drive will operate.
1
(0, 1)
0 : IPM Motor
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...