SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
705
When you input the Up command, the frequency reference will increase. When you input the Down command,
the frequency reference will decrease.
The Up and Down commands have priority over all other frequency references. When you enable the Up/Down
command, the drive will ignore these frequency references:
•
Frequency reference from Keypad
[b1-01 = 0]
•
Frequency reference from Analog Input
[b1-01 = 1]
•
Frequency reference from Pulse Train Input
[b1-01 = 4]
■
65: Up2 Command
Setting
Function
Description
65
Up2 Command
Sets the function to increase the frequency reference bias value to accelerate the motor when the terminal is activated. Set this
function and
H1-xx = 66 [Dw2 Command]
together.
When you activate the terminal set for Up2 Command, the bias will increase. When you activate the terminal set
for Down 2 Command, the bias will decrease. When you activate or deactivate the two commands, the drive will
hold the frequency reference.
gives information about the relation between operation of the Up/Down
2 Command and
d4-01
,
d4-03
,
d4-05
.
Note:
•
When using this function, set the optimal bias limit value with
d4-08 and d4-09 [Up/Dw2 Bias Upper Limit and Up/Dw2 Bias Lower
Limit]
.
•
Refer to
“
d4: FREQUENCY UP/DOWN
”
for more information.
Table 12.43 Up 2 Command, Down 2 Command
Func
tion
Frequency
Reference Source
d4-03
d4-05
d4-01
Operation
Storing the Frequency Reference or
Frequency Bias
1
Multi-step speed
reference
0.00
0
0
•
When the Up 2 Command is active, the drive
accelerates the motor (increases the bias value).
•
When the Down 2 Command is active, the
drive decelerates the motor (decreases the bias
value)
•
When the Up 2 Command and Down 2
Command are not active and when the Up 2
Command and Down 2 Command are active,
the drive holds the output frequency (holds the
bias value).
•
When the frequency changes, it will reset the
bias.
•
For all other statuses, the drive will follow the
frequency reference.
Not stored.
2
1
When the bias value and frequency reference are
constant for 5 seconds after the frequency
reference hold starts, the drive will add the bias
value to the enabled frequency reference, then
reset.
3
1
-
•
When the Up 2 Command is active, the drive
accelerates the motor.
•
When the Down 2 Command is active, the
drive decelerates the motor.
•
For all other statuses, the drive will follow the
frequency reference.
Not stored.
4
Multi-step speed
reference
> 0
-
0
•
When the Up 2 Command is active, the drive
accelerates the motor to
“
Freq Ref
d4-
03
”
(the bias value will increase to the value set
in
d4-03
).
•
When the Down 2 Command is active, the
drive decelerates the motor to
“
Freq Reference -
d4-03
”
(the bias value will decrease to the value
set in
d4-03
).
•
When the Up 2 Command and Down 2
Command are not active and when the Up 2
Command and Down 2 Command are active,
the drive holds the output frequency (holds the
bias value).
•
When the frequency changes, it will reset the
bias.
•
For all other statuses, the drive will follow the
frequency reference.
Not stored.
5
1
When the bias value and frequency reference are
constant for 5 seconds after the frequency
reference hold starts, the drive will add the bias
value to the enabled frequency reference, then
reset.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...