SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
151
*4
If
T1-12 = 1 [Test Mode Selection = Yes]
, when you run the motor in Drive Mode for the first time after Auto-Tuning, the drive will
automatically set
E2-02 [Mot Rated Slip]
and
E2-03 [Mot No-Load Current]
.
*5
Input this value when
T1-01 [Auto-tuning Mode Selection]
= 0 Hz.
*6
Set the same value to No-Load Voltage as
T1-03 [Motor Rated Voltage]
to get the same characteristics using Yaskawa 1000-Series
drives or other legacy models.
◆
Auto-Tuning for PM Motors
This section gives information about Auto-Tuning for PM motors. Set these parameters for Auto-Tuning:
•
Motor parameters
E1-xx [E1: V/F PARAMETER MOTOR 1], E5-xx [E5: PM MOTOR SETTINGS]
•
Speed feedback detection uses
F1-xx [F1: ENCODER]
(only with PM CLVector)
Table 4.9 Auto-Tuning for PM Motors
Method
Parameter Settings
Applicable When/Advantages
Applicable Control Method
(Value of A1-02 [Control Method])
PM OLVector
(5)
PM AOLVector
(6)
PM CLVector
(7)
PM Motor Parameter Settings
T2-01 = 0
•
When the information from the motor test report or
motor nameplate is not available.
•
Rotational/Stationary Auto-Tuning that energizes
the motor is not done. Manually input the necessary
motor parameters.
×
×
×
PM Static Full AutoTune
T2-01 = 1
•
When the information from the motor test report or
motor nameplate is not available.
Note:
With Stationary Auto-Tuning, the energized drive
stays stopped for approximately 1 minute. During
this time, the drive automatically measures the
necessary motor parameters.
×
×
×
PM Static R Autotune
T2-01 = 2
•
After Auto-Tuning, the wiring distance between the
drive and motor changed by 50 m or more.
•
When the motor output and drive capacity are
different.
×
×
×
Encoder Offset Autotune
T2-01 = 3
•
When you do not know the encoder Z-pulse offset.
•
When the encoder was replaced
•
If you have compensated for the deviation from Z
phase (Δθ).
Note:
The motor will rotate slowly while the drive
measures the encoder base position.
-
-
×
PM Rotary Autotune
T2-01 = 4
•
When the information from the motor test report or
motor nameplate is available.
•
When you can decouple the motor and load the
motor can rotate freely while Auto-Tuning.
Values measured during Auto-Tuning are
automatically set to the motor parameters.
×
×
×
■
Input Data for PM Motor Auto-Tuning
To do Auto-Tuning, input data for the items in the following tables that have an "×". Before starting Auto-Tuning,
prepare the motor test report or record the information on the motor nameplate as a reference.
Table 4.10 Input Data for PM Motor Auto-Tuning
Input Data
Unit
Auto-Tuning Method
(Value of T2-01 [PM AutoTune Mode Select])
PM Motor Parameter Settings
(0)
PM Static Full
AutoTune
(1)
PM Static R Autotune
(2)
A1-02 [Control Method]
-
5, 6, 7
5
6, 7
5
6, 7
5, 6, 7
T2-02 [PMMot Code Selection]
-
Motor code of Yaskawa
motor
-
-
-
T2-03 [PMMot Motor Type]
-
-
-
-
×
×
-
T2-04 [PMMot Rated Power]
kW
-
×
×
×
×
-
T2-05 [PMMot Rated Voltage]
V
-
×
×
×
×
-
T2-06 [PMMot Rated Current]
A
-
×
×
×
×
x
T2-07 [PMMot Base Frequency]
Hz
-
×
-
×
-
-
T2-08 [PMMot Poles Number]
-
-
×
×
×
×
-
T2-09 [PMMot Base Speed]
rpm
-
-
×
-
×
-
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...