SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
607
Note:
The drive detects
oPE11 [Carrier Frequency Setting Error]
when these conditions are correct at the same time:
•
C6-04 ≥ C6-03
•
C6-05 ≥ 6
■
C6-05 Carrier Freq Proportional Gain
No.
(Hex.)
Name
Description
Default
(Range)
C6-05
(0227)
Carrier Freq Proportional
Gain
Sets the proportional gain for the carrier frequency. Set
C6-02 = F [Carrier Frequency Selection
= User Defined (C6-03 to C6-05)]
to set this parameter.
Determined by C6-02
(0 - 99)
Set
C6-03 [Carrier Upper Frequency Limit]
,
C6-04 [Carrier Lower Frequency Limit]
, and
C6-05
to make the
carrier frequency change linearly with the output frequency.
■
C6-09 Carrier@Autotune Rotational
No.
(Hex.)
Name
Description
Default
(Range)
C6-09
(022B)
Carrier@Autotune
Rotational
Sets the Auto-Tuning carrier frequency. Usually it is not necessary to change this setting.
0
(0, 1)
If you do Auto-Tuning to a high-frequency motor or low-impedance motor and set a low carrier frequency,
oC
[Overcurrent]
can occur. To prevent
oC
, you can set the carrier frequency to a high value, then set
C6-09 = 1
.
The procedure to set the carrier frequency when the
A1-02 [Control Method]
setting changes.
•
When
A1-02 = 2 to 4 [OLVector, CLVector, or Adv OLVector]
, set
C6-02 = F [Carrier Frequency Selection =
User (C6-03 to C6-05)]
and then increase the value set to
C6-03 [Carrier Upper Frequency Limit]
.
•
When
A1-02 = 5 to 7 [PM OLVector, PM AOLVector, or PM CLVector]
, use
C6-02
to increase the carrier
frequency.
0 : 5kHz
Note:
When
A1-02 = 5, 6, or 7
, the carrier frequency is 2 kHz.
1 : use C6-03
Note:
When
A1-02 = 5, 6, or 7
, the carrier frequency is the value set to
C6-02
.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...