SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
■
C3-28 Adaptative Slip Control Mode
No.
(Hex.)
Name
Description
Default
(Range)
C3-28
(1B5B)
Expert
Adaptative Slip Control
Mode
Sets the slip compensation function mode.
0
(0, 1)
0 : Normal
1 : Advanced
Note:
Set
C3-28 = 0
for better torque precision. If the torque precision does is not better, set
C3-28 = 1
and increase the value of
n4-65 [HF
FlxEstim Response]
or
n4-66 [LF FlxEstim Response]
in 0.1-unit increments. Then, you must do Rotational Auto-Tuning.
◆
C4: TORQUE COMPENSATION
Torque compensation is a function that increases voltage to increase output torque as compensation for
insufficient torque production at start-up or low-speed operation.
Voltage drops due to motor winding resistance cause torque generating voltage to decrease, which causes
insufficient torque. If the main circuit cable connecting the drive and motor is long, this can also cause insufficient
torque due to voltage drops.
Note:
Set the motor parameters and V/f pattern properly before setting
C4 parameters
.
■
C4-01 Trq Comp Gain
No.
(Hex.)
Name
Description
Default
(Range)
C4-01
(0215)
RUN
Trq Comp Gain
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when
operating multiple motors.
Determined by A1-02
(0.00 - 2.50)
In V/f Control or CL-V/f Control, adjust the value in 0.05 unit increments for these conditions:
•
When torque is not sufficient during low-speed operation of 10 Hz or less, increase the setting value
•
When there is vibration in the motor or when the motor hunts when operating the drive with a light load,
decrease the setting value
•
When you use a long motor cable, increase the setting value.
Note:
•
Adjust
C4-01
to make sure that the output current is not more than the drive rated current during low-speed operation.
•
In usual conditions, do not change this parameter in Open Loop Vector Control. It can have a negative effect on torque precision.
•
In usual conditions, do not change this parameter in PM Open Loop Vector Control. Setting this value too high can cause
overcompensation and motor oscillation.
■
C4-02 Trq Comp Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
C4-02
(0216)
RUN
Trq Comp Delay Time
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Determined by A1-02
(0 - 60000 ms)
It can be necessary to adjust this parameter in these conditions:
•
If there is vibration in the motor, increase the setting.
•
If the motor speed or motor torque response is too slow, decrease the setting.
■
C4-03 Trq Comp@FWD Start
No.
(Hex.)
Name
Description
Default
(Range)
C4-03
(0217)
Trq Comp@FWD Start
Sets the amount of torque reference for forward start as a percentage of the motor rated torque.
0.0%
(0.0 - 200.0%)
The drive uses the time constant set in
C4-05 [Trq Comp Time]
to apply compensation.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...