The drive output shuts off and the motor coasts to stop. Fault relay output terminal 1NO-1CM will activate, and
1NC-1CM will deactivate.
2 : Fast Stop (C1-09)
The drive uses the deceleration time set in
C1-09 [Fast Stop Time]
. Fault relay output terminal 1NO-1CM will
activate, and 1NC-1CM will deactivate.
3 : Alarm Only
The keypad shows
E5
, and the drive continues to operate.
Note:
Separately prepare safety protection equipment and systems, for example fast stop switches.
The output terminal set for
Alarm [H2-01 to H2-03 = 4]
activates.
■
F6-26 MLII bUS Err Detected
No.
(Hex.)
Name
Description
Default
(Range)
F6-26
(03CA)
MLII bUS Err Detected
Sets the number of times that the option must detect a
bUS
alarm to cause a
bUS [Option
Communication Error]
.
2 times
(2 - 10 times)
■
F6-30 PROFI-DP Address
No.
(Hex.)
Name
Description
Default
(Range)
F6-30
(03CB)
PROFI-DP Address
Sets the node address for PROFIBUS-DP communication. Restart the drive after changing this
setting.
0
(0 - 125)
Note:
•
Be sure to set a node address that is different than all other node addresses.
•
Node addresses 0, 1, and 2 are usually reserved for control, maintenance, and device self-diagnosis.
■
F6-31 PROFI-DP Clear Command Mode
No.
(Hex.)
Name
Description
Default
(Range)
F6-31
(03CC)
PROFI-DP Clear Command
Mode
Sets what the drive will do after it receives the Clear Mode command.
0
(0, 1)
0 : Reset
Resets drive settings, for example frequency reference and I/O settings.
1 : Hold Previous State
The drive keeps the same status as before it received the command.
■
F6-32 PROFI-DP Data Format Select
No.
(Hex.)
Name
Description
Default
(Range)
F6-32
(03CD)
PROFI-DP Data Format
Select
Sets the data format of PROFIBUS-DP communication. Restart the drive after changing this
setting.
0
(0 - 5)
Note:
The
H5-11 [Mbus ENTER Command Mode]
setting makes the RAM enter command necessary or not necessary to write parameters over
network communication. When
F6-32 = 0, 1, or 2
, the
H5-11
setting does not have an effect. The RAM enter command is always
necessary to write parameters.
0 : PPO Type
1 : Conventional
2 : PPO (bit0)
This function operates when bit 0 and bit 4 in the register STW have values of 1 (operate). Refer to the
PROFIBUS-DP communication manual for more information.
3 : PPO (Enter)
4 : Conv (Enter)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...