SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
823
•
The ratio between the motor inertia and machine inertia is less than 1:10
•
There are large current ripples
2 : 1:10-1:30
Use this setting in these conditions:
•
The ratio between the motor inertia and machine inertia is approximately 1:10 to 1:30
•
Parameter
n8-55 = 1
and the drive detects
STPo
because of an impact load or sudden acceleration/deceleration.
3 : 1:30-1:50
Use this setting in these conditions:
•
The ratio between the motor inertia and machine inertia is approximately 1:30 to 1:50
•
Parameter
n8-55 = 2
and the drive detects
STPo
because of an impact load or sudden acceleration/deceleration.
4 : >1:50
Use this setting in these conditions:
•
The ratio between the motor inertia and machine inertia is more than 1:50
•
Parameter
n8-55 = 3
and the drive detects
STPo
because of an impact load or sudden acceleration/deceleration.
■
n8-57 High-Freq Injection
No.
(Hex.)
Name
Description
Default
(Range)
n8-57
(0574)
High-Freq Injection
Sets the function that detects motor speed with high frequency injection.
0
(0, 1)
Note:
•
When there is high frequency injection, the motor will make an excitation sound.
•
When you use Zero Speed Control, set
E1-09 [Min Output Frequency] = 0.0
.
0 : Disabled
Use this setting with SPM motors. The speed control range is approximately 1:20.
When
n8-57 = 0
, you cannot set
E1-09 [Min Output Frequency]
≤ 1/20 of the value of
E1-06 [Base Frequency]
.
1 : Enabled
Use this setting with IPM motors. The speed control range changes to 1:100 for very accurate speed detection.
■
n8-62 Output Volt Limit Level
No.
(Hex.)
Name
Description
Default
(Range)
n8-62
(057D)
Expert
Output Volt Limit Level
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not necessary
to change this setting.
400 V Class: 400.0 V
(400 V Class: 0.0 - 460.0
V)
Set this parameter lower than the input power supply voltage.
■
n8-65 SpdFbk Gain@OV Suppression
No.
(Hex.)
Name
Description
Default
(Range)
n8-65
(065C)
Expert
SpdFbk Gain@OV
Suppression
Sets the gain of internal speed feedback detection suppression while the overvoltage suppression
function is operating as a magnification value. Usually it is not necessary to change this
parameter.
1.50
(0.00 - 10.00)
Adjust this parameter in these conditions:
•
If there is resonance or hunting when you use the overvoltage suppression function, increase the setting value.
•
If motor response is low when you use the overvoltage suppression function, decrease the setting value in 0.05-
unit increments.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...