11.16 A1-02 [Control Method] Dependent Parameters
SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
503
Parameter
Setting Range
Unit
Control Method
V/f Control
(0)
PG V/f Control
(1)
OLVector
(2)
CLVector
(3)
Adv OLVector
(4)
L1-01 Motor Cool Type for OL1
Calc
0 - 4
1
1
1
1
1
1
L3-05 StallP@RUN Enable
0 - 3
1
1
1
-
-
-
L3-20 DCBus VoltAdj Gain
0.00 - 5.00
0.01
1.00
1.00
0.30
0.30
0.30
L3-21 OVSup Acc/Dec Gain
0.10 - 10.00
0.01
1.00
1.00
1.00
1.00
1.00
L3-36 VibSup Gain@Accel
0.0 - 100.0
0.1
10.0
10.0
20.0
-
-
L4-01 SpAgree Det.Level
0.0 - 400.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
L4-02 SpAgree Det.Width
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
2.0 Hz
2.0 Hz
2.0 Hz
L4-03 SpAgree Det.Level(+/-)
-400.0 - +400.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
L4-04 SpAgree Det.Width(+/-)
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
2.0 Hz
2.0 Hz
2.0 Hz
L8-38 Carrier Reduction Mode
0 - 2
1
L8-40 Carrier Red Off-Delay Time
0.00 - 2.00
0.01 s
0.50
0.50
0.50
0.50
0.50
n1-15 PWM VOffset Calibration
0 - 2
1
1
1
1
1
2
o1-03 FrqDisplay Unit Selection
0 - 3
1
0
0
0
0
0
o1-04 V/f Pattern Unit for Display
0 - 1
1
-
-
-
0
0
*1
Drive models and 4103 to 4675 use these default settings when
C6-01 = 1 [ND/HD Duty Selection = ND Rating]
. Drive models
4140 to 4675 use these default settings when
C6-01 = 0 [ND/HD Duty Selection = HD Rating]
.
•
A1-02 = 2 [Control Method = OLVector]
:
2.00
•
A1-02 = 3, 4 [Control Method = CLVector, Adv OLVector]
:
0.05
*2
The default setting is 1000 ms for drive models 4103 to 4675.
*3
The default setting varies depending on the setting of
C6-01 [ND/HD Duty Selection]
.
*4
The setting range varies depending on the setting of
E5-03 [PM Mot Rated Current (FLA)]
when
A1-02 = 5 [Control Method = PM
OLVector]
.
*5
The default setting varies depending on drive model and
E1-03 [V/f Pattern Selection]
settings.
*6
This is the value for 200 V class drives. Double the value for 400 V class drives.
*7
The maximum value within the setting range is 100.0 when
A1-02 = 5 or 7 [Control Method = PM OLVector or PM CLVector]
.
*8
The setting range is -100.0 to 100.0 when
A1-02 = 5 or 7 [Control Method = PM OLVector or PM CLVector]
.
◆
Control Method for PM Motors and Simple Vector Control
No.
Setting Range
Unit
Control Method
PM OLVector
(5)
PM AOLVector
(6)
PM CLVector
(7)
EZ Vector
(8)
b2-01 ZSpd/DCI Threshold
0.0 - 10.0
0.1
0.5 Hz
1.0%
0.5%
1.0%
b2-04 DCInj Time@Stop
0.00 - 10.00
0.01 s
0.00
0.00
0.00
0.00
b3-01 SpSrch@Start Selection
0 - 1
1
0
0
1
0
b3-14 Speed Bi-Directional Search
0 - 1
1
1
1
1
1
b5-15 Sleep Start Level
0.0 - 400.0
0.1
0.0 Hz
0.0 %
0.0 %
0.0 %
b6-01 Dwell Ref.@Start
0.0 - 400.0
0.1
0.0 Hz
0.0 %
0.0 %
0.0 %
b6-03 Dwell Ref@Stop
0.0 - 400.0
0.1
0.0 Hz
0.0 %
0.0 %
0.0 %
b8-02 eSave Ctrl Gain
0.0 - 10.0
0.1
-
-
-
-
b8-03 eSave Filter Time
0.00 - 10.00
0.01 s
-
-
-
-
C1-11 Ac/Dec Switch Frequency
0.0 - 400.0
0.1
0.0 Hz
0.0 %
0.0 %
0.0 %
C2-01 Jerk@Start of Accel
0.00 - 10.00
0.01 s
1.00
0.20
0.20
1.00
C3-01 Slip Comp Gain
0.0 - 2.5
0.1
-
-
-
Determined by E9-
01
C3-02 Slip Comp Delay Time
0 - 10000
1 ms
-
-
-
200
C4-01 Trq Comp Gain
0.00 - 2.50
0.01
0.00
-
-
0.00
C4-02 Trq Comp Delay Time
0 - 10000
1 ms
100
-
-
100
C5-01 ASR PGain 1
0.00 - 300.00
0.01
10.00
10.00
20.00
10.00
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...