SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
599
Table 12.18 ASR Response and Possible Solutions
Problem
Possible Solutions
Speed response is slow.
•
Increase
C5-01/C5-03 [ASR PGain 1/ASR PGain 2]
.
•
Decrease
C5-02/C5-04 [ASR ITime 1/ASR ITime 2]
.
Overshoot or undershoot occurs at the end of acceleration
or deceleration.
•
Decrease
C5-01/C5-03
.
•
Increase
C5-02/C5-04
.
Vibration and oscillation occur at constant speed.
•
Decrease
C5-01/C5-03
.
•
Increase
C5-02/C5-04
.
•
Increase
C5-06 [ASR Delay Time]
.
Speed accuracy is unsatisfactory when you operate a
motor that has a large quantity of rated slip in Closed
Loop V/f Control.
•
Check the pulse number set to
F1-01 [Enc1 Pulse
Count (PPR)]
and the gear ratio to
F1-12 [Enc1 Gear
Teeth1]
and
F1-13 [Enc1 Gear Teeth2]
.
•
Make sure that you correctly set the pulse signal from
the encoder.
•
Check
U6-04 [ASR Output]
to make sure that the ASR
operates at its output limit set to
C5-05 [ASR Limit]
. If
the ASR is at the output limit, increase
C5-05
.
If
C5-12 = 1
or
C5-32 = 1 [Enabled]
in Closed Loop V/f
Control and over/undershoot occurs when you change
speeds.
-
•
Decrease
C5-01/C5-03
.
•
Increase
C5-02/C5-04
.
•
Decrease the value set to
C5-05
.
Oscillation at low speed and response is too slow at high
speed. Oscillation at high speed and response is too slow
at low speed.
-
•
Closed Loop V/f Control Mode:
Use
C5-03
and
C5-04
at maximum speed and
C5-01
and
C5-02
at minimum speed to set different ASR
settings.
•
Closed Loop Vector Control, PM Advanced Open
Loop Vector Control, and PM Closed Loop Vector
Control:
Use
C5-01
to
C5-04
to set the best ASR settings for
high and low speed. Use
C5-07 [ASR Gain Switch
Frequency]
to switch the ASR proportional gain and
ASR integral time as specified by the output
frequency.
■
C5-01 ASR PGain 1
No.
(Hex.)
Name
Description
Default
(Range)
C5-01
(021B)
RUN
ASR PGain 1
Sets the gain to adjust ASR response.
Determined by A1-02
(0.00 - 300.00)
The speed response increases as the gain increases. Usually, the gain increases with larger loads. Too much gain
causes vibration.
Note:
•
The drive usually sets Motor 1 ASR with
C5-01
and
C5-02 [ASR ITime 1]
. To use
C5-03 [ASR PGain 2]
as an alternative to
C5-01
set
H1-xx = 45 [MFDI Function Select = ASR Gain Switch]
. You can also use
C5-01
as an alternative to
C5-04 [ASR ITime 2]
when the
speed is less than or equal to the frequency set in
C5-07 [ASR Gain Switch Frequency]
.
•
The drive automatically adjusts
C5-01
in ASR Tuning.
■
C5-02 ASR ITime 1
No.
(Hex.)
Name
Description
Default
(Range)
C5-02
(021C)
RUN
ASR ITime 1
Sets the ASR integral time.
Determined by A1-02
(0.000 - 60.000 s)
An integral time that is too long will decrease the responsiveness of the speed control and decrease drive response
to dynamic changes in motor load. An integral time that is too short can cause oscillation.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...