4.8 Fine Tuning during Test Runs (Adjust the Control Function)
162
SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
◆
Advanced Open Loop Vector Control Method for PM
Table 4.22 Parameters for Fine Tuning the Drive (Advanced Open Loop Vector Control Method for PM)
Issue
Parameter Number
Solution
Default
Setting
Recommended Setting
•
Torque or speed response are
slow.
•
Hunting or oscillation
•
High speed
C5-01 [ASR PGain 1]
•
Low speed
C5-03 [ASR PGain 2]
•
If torque or speed response are slow, increase the
setting value in increments of 5.00.
•
If hunting or oscillation occur, decrease the setting
value.
10.00
5.00 - 30.00
•
High speed
C5-02 [ASR ITime 1]
•
Low speed
C5-04 [ASR ITime 2]
•
If torque or speed response are slow, decrease the
setting value.
•
If hunting or oscillation occur, increase the setting
value.
0.500 s
0.300 to 1.000 s
The drive cannot find ASR
proportional gain or integral time for
low speed or high speed.
C5-07 [ASR Gain Switch
Frequency]
Change the ASR proportional gain and ASR integral
time to conform to the output frequency.
0.0 %
0.0% to maximum rotation
speed
Hunting or oscillation
C5-06 [ASR Delay Time]
If the rigidity of the machine is unsatisfactory and
vibration is possible, increase the setting value in
increments of 10 ms.
16 ms
16 to 35 ms
Step-out
E1: V/F PARAMETER
MOTOR 1parameters, E5: PM
MOTOR SETTINGS
parameters
Refer to the motor nameplate or test report and set
E1:
V/F PARAMETER MOTOR 1
or
E5: PM MOTOR
SETTINGS
parameters correctly.
-
-
*1
The best values for a no-load operation are different than the best values for actual loading operation.
◆
Closed Loop Vector Control Method for PM
Table 4.23 Parameters for Fine Tuning the Drive (Closed Loop Vector Control Method for PM)
Issue
Parameter Number
Solution
Default
Setting
Recommended Setting
•
Torque or speed response are
slow.
•
Hunting or oscillation
•
High speed
C5-01 [ASR PGain 1]
•
Low speed
C5-03 [ASR PGain 2]
•
If torque or speed response are slow, increase the
setting value in increments of 5.00.
•
If hunting or oscillation occur, decrease the setting
value.
20.00
10.00 - 50.00
•
High speed
C5-02 [ASR ITime 1]
•
Low speed
C5-04 [ASR ITime 2]
•
If torque or speed response are slow, decrease the
setting value.
•
If hunting or oscillation occur, increase the setting
value.
0.500 s
0.300 to 1.000 s
The drive cannot find speed response
for low speed or high speed.
•
C5-07 [ASR Gain Switch
Frequency]
•
High speed
C5-01 [ASR PGain 1]
C5-02 [ASR ITime 1]
•
Low speed
C5-03 [ASR PGain 2]
C5-04 [ASR ITime 2]
Change the ASR proportional gain and ASR integral
time to conform to the output frequency.
0.0 %
0.0% to maximum rotation
speed
Hunting or oscillation
C5-06 [ASR Delay Time]
If the rigidity of the machine is unsatisfactory and
vibration is possible, increase the setting value in
increments of 10 ms.
4 ms
4 to 20 ms
Step-out
E1: V/F PARAMETER
MOTOR 1parameters,
E5: PM MOTOR SETTINGS
parameters
Refer to the motor nameplate or test report and set
E1:
V/F PARAMETER MOTOR 1
or
E5: PM MOTOR
SETTINGS
parameters correctly.
-
-
*1
The best values for a no-load operation are different than the best values for actual loading operation.
◆
EZ Open Loop Vector Control Method
Table 4.24 Parameters for Fine Tuning the Drive (EZ Open Loop Vector Control Method)
Issue
Parameter Number
Solution
Default
Setting
Recommended Setting
•
Torque or speed response are
slow.
•
Hunting or oscillation
•
High speed
C5-01 [ASR PGain 1]
•
Low speed
C5-03 [ASR PGain 2]
•
If torque or speed response are slow, increase the
setting value in increments of 5.00.
•
If hunting or oscillation occur, decrease the setting
value.
10.00
10.00 - 50.00
•
High speed
C5-02 [ASR ITime 1]
•
Low speed
C5-04 [ASR ITime 2]
•
If torque or speed response are slow, decrease the
setting value.
•
If hunting or oscillation occur, increase the setting
value.
0.500 s
0.300 to 1.000 s
The drive cannot find ASR
proportional gain or integral time for
low speed or high speed.
C5-07 [ASR Gain Switch
Frequency]
Change the ASR proportional gain and ASR integral
time to conform to the output frequency.
0.0%
0.0% to maximum rotation
speed
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...