SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
819
The drive uses the polar pull-in current to attract the rotor after it detects the initial rotor position. When you
increase the value of this parameter, the starting torque also increases.
•
If the motor does not track correctly at the time of the polar attraction, increase the value in 10% increments. If
you set the value too high, the drive will detect
oL2 [Drive Overloaded].
•
If the motor oscillates at the time of the polar attraction, decrease the value in 10% increments.
Note:
Set
A1-02 = 7 [Control Method = PM CLVector]
and do Rotational Auto-Tuning or Z Pulse Offset Tuning to use this function.
■
n8-03 Current Start Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-03
(0542)
Current Start Time
Sets the length of the Current Starting Time, which is used for Z Pulse Offset Tuning. Usually it is
not necessary to change this parameter.
1.5 s
(1.5 - 5.0 s)
Sets the length of time of pull-in current when the drive detects the motor magnetic pole of the rotors.
Note:
If the motor oscillates at the time of the polar attraction, increase the value in 0.5 s increments. If the value is too high, the drive can
detect
oL2 [Drive Overloaded]
.
■
n8-04 Pole Align Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-04
(0543)
Expert
Pole Align Time
Sets the length of the Polar Attraction Time, which is used for Z Pulse Offset Tuning. Usually it is
not necessary to change this setting.
1.5 s
(1.5 - 5.0 s)
Sets the length of time that the pull-in current flows when the drive detects the motor magnetic pole of the rotors.
Note:
If the motor oscillates at the time of the polar attraction, increase the value in 0.5 s increments. If you set the value too high, the drive
will detect
oL2 [Drive Overloaded]
.
■
n8-11 Observ.Calc Gain2
No.
(Hex.)
Name
Description
Default
(Range)
n8-11
(054A)
Observ.Calc Gain2
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
Determined by n8-72
(0.0 - 1000.0)
Note:
When
n8-72 = 1 [Spd Obs. Method Selection = Method 1]
, the default value is 50.0. When
n8-72 = 2 [Method 2]
, the default value is
30.0 for drives that have a maximum capacity of 4023. The default is 50.0 for 4031 and larger models.
■
n8-14 Polar Comp Gain3
No.
(Hex.)
Name
Description
Default
(Range)
n8-14
(054D)
Expert
Polar Comp Gain3
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
2.000
(0.000 - 20.000)
■
n8-15 Polar Comp Gain4
No.
(Hex.)
Name
Description
Default
(Range)
n8-15
(054E)
Expert
Polar Comp Gain4
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
2.000
(0.000 - 20.000)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...