492
SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
No.
(Hex.)
Name
Description
MFAO Signal Level
Ref.
U1-12
(004B)
Drive Status
Shows drive status where 1 = (ON) and 0 = (OFF).
For example, U1-12 shows
“
00000101
”
during run with the Reverse Run command.
bit 0 : During run
bit 1 : During zero-speed
bit 2 : During reverse
bit 3 : During fault reset signal input
bit 4 : During speed agreement
bit 5 : Drive ready
bit 6 : During minor fault detection
bit 7 : During fault detection
No signal output
available
-
U1-13
(004E)
Terminal AI1 Input Lv
Shows the signal level of terminal AI1.
Unit: 0.1%
10 V = 100% (-10 V to
+10 V)
-
U1-14
(004F)
Terminal AI2 Input Lv
Shows the signal level of terminal AI2.
Unit: 0.1%
10 V = 100% (-10 V to
+10 V)
-
U1-15
(0050)
Terminal AI3 Input Lv
Shows the signal level of terminal AI3.
Unit: 0.1%
0 V = 100% (-10 V to
+10 V)
-
U1-16
(0053)
SFS Output Frequency
Shows the output frequency after soft start. Shows the frequency with acceleration and
deceleration times and Jerk Control. Parameter
o1-03 [FrqDisplay Unit Selection]
selects the units.
Unit: 0.01 Hz
10 V = Max. frequency
(-10 V to +10 V)
-
U1-17
(0058)
DI-A3 Input Status
Shows the reference value input from DI-A3 option.
Shows the input signal for DI-A3 in hexadecimal as set in
F3-01 [D.In Funct
Selection]
.
3FFFF: Set (1 bit) + Sign (1 bit) + 16 bit
No signal output
available
-
U1-18
(0061)
oPE Fault Parameter
Shows the parameter number that caused the
oPE02 [Parameter Range Setting Error]
or
oPE08 [Parameter Selection Error]
.
No signal output
available
-
U1-19
(0066)
Modbus Err.Code
Shows the contents of the Modbus communication error where 1 = (error) and 0 = (no
error).
For example,
U1-19
shows
“
00000001
”
when a CRC error occurs.
bit 0 : CRC Error
bit 1 : Data Length Error
bit 2 : Not used (normal value of 0).
bit 3 : Parity Error
bit 4 : Overrun Error
bit 5 : Framing Error
bit 6 : Timed Out
bit 7 : Not used (normal value of 0).
No signal output
available
-
U1-21
(0077)
AI-A3 Term V1 Level
Shows the analog reference of terminal V1 on analog input option card AI-A3.
Unit: 0.1%
10 V = 100% (-10 V to
+10 V)
-
U1-22
(072A)
AI-A3 Term V2 Level
Shows the analog reference of terminal V2 on analog input option card AI-A3.
Unit: 0.1%
10 V = 100% (-10 V to
+10 V)
-
U1-23
(072B)
AI-A3 Term V3 Level
Shows the analog reference of terminal V3 on analog input option card AI-A3.
Unit: 0.1%
10 V = 100% (-10 V to
+10 V)
-
U1-24
(007D)
Input Pulse Monitor
Shows the frequency to pulse train input terminal PI.
Unit: 1 Hz
Determined by H6-02
-
U1-25
(004D)
SoftNumber Flash
Shows the FLASH ID.
No signal output
available
-
U1-26
(005B)
SoftNumber ROM
Shows the ROM ID.
No signal output
available
-
U1-50
(1199)
Expert
Virt. Analog Input
Shows the virtual analog input value.
Determined by H7-40
-
U1-91
(154E)
Expert
Output Voltage
Shows the drive internal output voltage reference.
Unit: 0.1 V
400 V class: 10 V = 400
Vrms
-
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...