SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
805
Adjust this parameter in these conditions:
•
When
n1-01 = 2, 3 [HuntPrev Selection = Enabled (High Carrier), ]
: If oscillation occurs when you operate a
motor with a light load, increase the setting value in 0.1-unit increments.
•
When
n1-01 = 2, 3
, if the motor stalls: Decrease the setting value in 0.1-unit increments.
■
n1-08 CurrDetect Method
No.
(Hex.)
Name
Description
Default
(Range)
n1-08
(1105)
Expert
CurrDetect Method
Sets how the drive decreases the motor vibration that is caused by leakage current. Usually it is
not necessary to change this setting.
1
(1, 2)
1 : 2-Phases
2 : 3-Phases
Note:
Set this parameter to 2 to suppress motor vibrations caused by leakage current when the wiring distance is long.
■
n1-13 DCBus Stab.Control
No.
(Hex.)
Name
Description
Default
(Range)
n1-13
(1B59)
Expert
DCBus Stab.Control
Sets the oscillation suppression function for the DC bus voltage.
0
(0, 1)
0 : Disabled
1 : Enabled
Note:
If the DC bus voltage does not become stable with light loads and the drive detects
ov [Overvoltage]
, set this parameter to 1.
■
n1-14 DCBus Stab Time
No.
(Hex.)
Name
Description
Default
(Range)
n1-14
(1B5A)
Expert
DCBus Stab Time
Sets a length of time for the drive to suppress oscillation in relation to the DC bus voltage. Set
n1-
13 = 1 [DCBus Stab.Control = Enabled]
to enable this parameter.
100.0 ms
(50.0 - 500.0 ms)
Note:
Adjust this parameter in 100 ms increments.
■
n1-15 PWM VOffset Calibration
No.
(Hex.)
Name
Description
Default
(Range)
n1-15
(0BF8)
Expert
PWM VOffset Calibration
Sets the calibration method that the drive uses to decrease torque/current ripple.
Determined by A1-02
(1 - 3)
This calibration function lets the drive suppress the torque ripple of a motor. Usually it is not necessary to change
this setting.
1 : No Calibration
2 : Calib@Next Start
3 : Calib@Every Start
■
n1-16 HuntPrev HiFc Gain
No.
(Hex.)
Name
Description
Default
(Range)
n1-16
(0BFB)
HuntPrev HiFc Gain
Sets the gain for the hunting prevention function. This parameter functions best with a high carrier
frequency. Usually it is not necessary to change this setting.
Determined by o2-04
(0.00 - 2.50)
Set
n1-01 = 3 [HuntPrev Selection = ]
to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...