618
SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
Remove the Saved Frequency Reference Value
The procedure to remove the saved frequency reference value is different for different functions. Use these
methods to remove the value:
•
Release the input programmed for
Ac/Dec Hold [H1-xx = 17]
.
•
Set an Up or Down command while no Run command is active.
•
Use the Up/Down 2 Command to set
d4-06 = 0.0
or set
d4-06 = 0.0
during stop.
■
d4-03 Up/Dw2 Bias Step Frequency
No.
(Hex.)
Name
Description
Default
(Range)
d4-03
(02AA)
RUN
Up/Dw2 Bias Step
Frequency
Sets the bias that the Up/Down 2 function adds to or subtracts from the frequency reference.
0.00 Hz
(0.00 - 99.99 Hz)
The operation is different for different setting values:
•
Setting d4-03 = 0.00 Hz
When
H1-xx = 65, 66 [Up2 Command, Dw2 Command]
is active, the drive uses the accel/decel times set in
d4-
04 [Up/Dw2 Ramp Selection]
to increase or decrease the bias value.
Figure 12.60 Up/Down 2 Bias when d4-03 = 0.00 Hz
•
Setting d4-03 ≠ 0.00 Hz
When the
H1-xx = 65, 66 [Up2 Command, Dw2 Command]
is active, the drive increases or decreases the bias
in steps for the value set in
d4-03
. The drive uses the acceleration and deceleration times set in
d4-04
.
Figure 12.61 Up/Down 2 Bias when d4-03
≠
0.00 Hz
■
d4-04 Up/Dw2 Ramp Selection
No.
(Hex.)
Name
Description
Default
(Range)
d4-04
(02AB)
RUN
Up/Dw2 Ramp Selection
Sets the acceleration and deceleration times for the Up/Down 2 function to apply the bias to the
frequency reference.
0
(0, 1)
0 : Current Ac/Dec Time
Use the active acceleration and deceleration times to increase or decrease the bias.
1 : Ac/Dec 4
Use
C1-07 [Accel Time 4]
and
C1-08 [Decel Time 4]
to increase or decrease the bias.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание Q2A
Страница 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Страница 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Страница 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 357: ...SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 357 9 Disposal 9 1 Safety Precautions 358 9 2 Disposal Instructions 359...
Страница 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Страница 526: ...11 20 Parameters Changed by PM Motor Code Selection 526 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...