VIII
After Use
CAUTION
•
After using the device, remove the near point rod from the device and store
it in a secure location.
If the near point rod is not removed, it may topple over and injury may occur.
•
If the device will not be used for a long time, disconnect the power cable
from the wall outlet.
Settled dust may collect moisture, and short circuit or fire may result.
•
Occasionally clean the prongs of the power plug with a dry cloth.
If dust settles between the prongs, it may collect moisture, and short circuit or fire may
result.
•
Do not pull the power cord to disconnect the plug from an outlet.
This can damage the metal core of the cord and may result in electric shock, short cir-
cuit or fire.
•
Before moving the device to another location, disconnect all the cords and
cables.
Maintenance
CAUTION
•
Only NIDEK service representatives or hospital personnel trained by NIDEK
should attempt to modify or touch the interior of the device and/or upgrade
the software.
NIDEK is not responsible for any accidents resulted from improper servicing.
•
When performing maintenance work, secure sufficient maintenance space.
Maintenance work in an insufficient space may result in injury.
•
When sending the device back to NIDEK for repair or maintenance, wipe the
surfaces of the device (especially, the areas that come into patient contact)
with a clean cloth dampened with ethyl alcohol for disinfection.
•
Never use organic solvents such as a paint thinner to clean the exterior of
the device.
It may ruin the surface of the device.
•
When cleaning the measuring window, be sure to remove any dust with a
blower brush and wipe lightly with a soft cloth.
Wiping the window without removing dust may scratch the lens coating and impair
measurement of the power or visual acuity.
•
To ensure the continued safe use of the device, it is recommended that the
manager of this device make sure that maintenance and preventive
inspection are performed at least once a year.
For details of maintenance and preventive inspection, ask NIDEK or your authorized
distributor. If the manager of this device cannot perform the maintenance and preven-
tive inspection, contact NIDEK or your authorized distributor.
161221687130 承認済
Uncontrolled copy when printed.
Содержание RT-5100
Страница 12: ...X 161221687130 承認済 Uncontrolled copy when printed ...
Страница 18: ... XVI 161221687130 承認済 Uncontrolled copy when printed ...
Страница 46: ...28 BEFORE USE Getting Started and Exiting 161221687130 承認済 Uncontrolled copy when printed ...
Страница 226: ...208 TEST METHOD Visual Acuity Test by ETDRS chart 161221687130 承認済 Uncontrolled copy when printed ...
Страница 274: ...256 MAINTENANCE List of Replacement Parts 161221687130 承認済 Uncontrolled copy when printed ...
Страница 302: ...284 EMC ELECTROMAGNETIC COMPATIBILITY 161221687130 承認済 Uncontrolled copy when printed ...