APPENDIX
App. - 55
Data type
Description
Home position [command unit]
The home position is displayed.
Main circuit bus voltage
The voltage of main circuit converter (between P+ and N-) is displayed.
Regenerative load ratio
The ratio of regenerative power to permissible regenerative power is displayed in %.
Effective load ratio
The continuous effective load current is displayed.
The effective value is displayed considering a rated current as 100%.
Peak load ratio
The maximum torque generated is displayed.
The highest value in the past 15 s is displayed, with the rated torque being 100 %.
Estimate inertia moment ratio
The set ratio of the load inertia moment to the servo motor shaft inertia moment is
displayed.
Model loop gain
The model loop gain value is displayed.
LED display
The value shown on the 7-segment LED display of the servo amplifier is displayed.
Load-side encoder information 1
When an incremental type linear encoder is used for the load-side encoder, the Z-phase
counter of the load-side encoder is displayed by encoder pulses.
When an absolute position type linear encoder is used for the load-side encoder, the
encoder absolute position is displayed.
Load-side encoder information 2
When an incremental type linear encoder is used for the load-side encoder, the display
shows 0.
When an absolute position type linear encoder is used for the load-side encoder, the
display shows 0.
When a rotary encoder is used for the load-side encoder, the display shows the multi-
revolution counter value of the encoder.
Speed feedback
The servo motor speed is displayed.
Servo motor thermistor temperature
The thermistor temperature is displayed for the servo motor with a thermistor.
For the servo motor without thermistor, "9999" is displayed.
For the servo motor with a thermistor, refer to each servo motor instruction manual.
Z-phase counter
The Z-phase counter is displayed in the encoder pulse unit.
For an incremental type linear encoder, the Z-phase counter is displayed. The value is
counted up from 0 based on the home position (reference mark).
For an absolute position type linear encoder, the encoder absolute position is displayed.
Module power consumption
The module power consumption is displayed.
The positive value is displayed in power running. The negative value is displayed in
regeneration.
Module integral power consumption
The module integral power consumption is displayed.
Disturbance torque
The difference between the torque necessary to drive the servo motor and the actually
required torque (Torque current value) is displayed as the disturbance torque.
Instantaneous torque
The instantaneous torque is displayed.
The value of torque being occurred is displayed in real time considering a rated torque as
100%.
Overload alarm margin
The margins to the levels which trigger [AL. 50 Overload 1] and [AL. 51 Overload 2] are
displayed in percentage.
Error excessive alarm margin
The margin to the level which triggers the error excessive alarm is displayed in units of
encoder pulses.
The error excessive alarm occurs at 0 pulses.
Settling time
The time (Settling time) after command is completed until INP (In-position) turns on is
displayed.
Overshoot amount
The overshoot amount during position control is displayed in units of encoder pulses.
Servo motor side/load-side position
deviation
During fully closed loop control, a deviation between servo motor side position and load-
side position is displayed.
The number of pulses displayed is in the load-side encoder pulse unit.
Servo motor side/load-side speed
deviation
During fully closed loop control, a deviation between servo motor side speed and load-side
speed is displayed.
Internal temperature of encoder
The internal temperature of encoder is displayed. "0" is displayed for the linear servo
motor. When an encoder communication error occurs, the last value will be displayed
before the error.
This is available with servo amplifiers with software version C4 or later.
Machine diagnostic status
The current status of the machine diagnostic function is displayed.
Friction estimation data
The friction estimation data estimated by the machine diagnostic function is displayed.
Vibration estimation data
The vibration estimation data estimated by the machine diagnostic function is displayed.
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...