11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 36
(c) Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding of the shielded wire to the SD terminal of the connector
provides a sufficient effect. However, the effect can be increased when the shielded wire is
connected directly to the grounding plate as shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the grounding plate.
[Unit: mm]
Strip the cable sheath of
the clamped area.
cutter
cable
Cable clamp
(A, B)
Cable
Grounding
plate
External conductor
Clamp section diagram
40
Dimensions
[Unit: mm]
Grounding plate
(Note) M4 screw
11
3
6
C
A
6
22
17.5
35
35
7
24
0 -0.
2
B ± 0.3
2-
φ
5 hole
mounting hole
[Unit: mm]
Clamp section diagram
L or less
10
30
24
+ 0.
3
0
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model A
B
C
Accessory
fittings
Clamp fitting
L
AERSBAN-DSET
100
86
30
Clamp A: 2 pcs.
A 70
AERSBAN-ESET
70
56
Clamp B: 1 pc.
B 45
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...