6. NORMAL GAIN ADJUSTMENT
6 - 9
(b) Amplifier command method
Input a permissible travel distance. Input it in the load-side resolution unit for the fully closed loop
control mode, and in the servo motor-side resolution unit for other control modes. In the amplifier
command method, the servo motor will be operated in a range between "current value ± permissible
travel distance". Input the permissible travel distance as large as possible within a range that the
movable part does not collide against the machine. Inputting a small permissible travel distance
decreases the possibility that the moving part will collide against the machine. However, the
estimation accuracy of the load to motor inertia ratio may be lower, resulting in improper tuning.
Also, executing the one-touch tuning in the amplifier command method will generate a command for
the following optimum tuning inside the servo amplifier to start the tuning.
Servo motor
speed
Servo motor
speed (Note)
Forward
rotation
0 r/min
Reverse
rotation
Dwell time (Note)
Deceleration
time constant
(Note)
Travel distance (Note)
Acceleration
time constant
(Note)
Note. It will be automatically generated in the servo amplifier.
Fig. 6.2 Command generated by one-touch tuning in the amplifier command method
Item Description
Travel distance
An optimum travel distance will be automatically set in the range not exceeding the user-inputted permissible
travel distance with MR Configurator2.
Servo motor speed
A speed not exceeding 1/2 of the rated speed and overspeed alarm detection level ([Pr. PC08]) will be
automatically set.
Acceleration time
constant
Deceleration time
constant
An acceleration time constant/deceleration time constant will be automatically set so as not to exceed 60% of the
rated torque and the torque limit value set at the start of one-touch tuning in the amplifier command method.
Dwell time
A dwell time in which the one-touch tuning error "C004" does not occur will be automatically set.
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...