5. PARAMETERS
5 - 35
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB53 VRF22 Vibration
suppression control 2 - Resonance frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
value out of the range is set, the vibration suppression control will be disabled. Refer
to section 7.1.5 for details.
100.0
[Hz]
0.1 to
300.0
Each
PB54
VRF23 Vibration suppression control 2 - Vibration frequency damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used. Refer to
section 7.1.5 for details.
0.00
0.00 to
0.30
Each
PB55
VRF24 Vibration suppression control 2 - Resonance frequency damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used. Refer to
section 7.1.5 for details.
0.00
0.00 to
0.30
Each
PB56 VRF21B Vibration suppression control 2 - Vibration frequency after gain switching
Set the vibration frequency for vibration suppression control 2 when the gain switching
is enabled.
When you set a value less than 0.1 Hz, the value will be the same as [Pr. PB52].
To enable this, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 2 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ 2 _)".
"Gain switching selection" in [Pr. PB26] is "Control command from controller is
enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the servo
motor or linear servo motor stops.
0.0
[Hz]
0.0 to
300.0
Each
PB57 VRF22B Vibration suppression control 2 - Resonance frequency after gain switching
Set the resonance frequency for vibration suppression control 2 when the gain
switching is enabled.
When you set a value less than 0.1 Hz, the value will be the same as [Pr. PB53].
To enable this, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 2 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ 2 _)".
"Gain switching selection" in [Pr. PB26] is "Control command from controller is
enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the servo
motor or linear servo motor stops.
0.0
[Hz]
0.0 to
300.0
Each
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...