17. APPLICATION OF FUNCTIONS
17 - 18
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
common
PX03 VRFTX Vibration suppression control tuning mode (advanced vibration suppression control
II)
This is used to set the vibration suppression control tuning. Refer to (5) (C) in this
section for details.
Refer to Name and
function column.
Each
axis
Setting
digit
Explanation
Initial
value
_ _ _ x
For manufacturer setting
0h
_ _ x _
Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression
control 2. To enable the digit, select "3 inertia mode (_ _
_ 1)" of "Vibration suppression mode selection" in [Pr.
PX02 Function selection X-1].
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PX04 VRF21 Vibration
suppression
control 2 - Vibration frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PX02].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PX03], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If
a value out of the range is set, the vibration suppression control will be disabled.
Refer to section 17.1.9 (5) (2) for details.
100.0
[Hz]
0.1
to
300.0
Each
axis
PX05 VRF22 Vibration
suppression control 2 - Resonance frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PX02].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PX03], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If
a value out of the range is set, the vibration suppression control will be disabled.
Refer to section 17.1.9 (5) (2) for details.
100.0
[Hz]
0.1
to
300.0
Each
axis
PX06
VRF23 Vibration suppression control 2 - Vibration frequency damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PX02].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PX03], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
Refer to section 17.1.9 (5) (2) for details.
0.00 0.00
to
0.30
Each
axis
PX07
VRF24 Vibration suppression control 2 - Resonance frequency damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PX02].
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PX03], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
Refer to section 17.1.9 (5) (2) for details.
0.00 0.00
to
0.30
Each
axis
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...