4. STARTUP
4 - 13
(2) Indication list
Indication Status
Description
Initializing
System check in progress
A b
Initializing
Power of the servo amplifier was switched on at the condition that the power of
the servo system controller is off.
The control axis No. set to the auxiliary axis number setting switches (SW2-5 and
SW2-6) and the axis selection rotary switch (SW1) do not match the one set to the
servo system controller.
A servo amplifier malfunctioned, or communication error occurred with the servo
system controller or the previous axis servo amplifier. In this case, the indication
changes as follows.
"Ab"
→
"AC"
→
"Ad"
→
"Ab"
The servo system controller is malfunctioning.
A b .
Initializing
During initial setting for communication specifications
A C
Initializing
Initial setting for communication specifications completed, and then it synchronized
with servo system controller.
A d
Initializing
During initial parameter setting communication with servo system controller
A E
Initializing
During the servo motor/encoder information and telecommunication with servo
system controller
A F
Initializing
During initial signal data communication with servo system controller
A H
Initializing
completion
The process for initial data communication with the servo system controller is
completed.
A A
Initializing
standby
The power supply of servo system controller is turned off during the power supply of
servo amplifier is on.
(Note 1) b # #
Ready-off
The ready off signal from the servo system controller was received.
(Note 1) d # #
Servo-on
The ready off signal from the servo system controller was received.
(Note 1) C # #
Servo-off
The ready off signal from the servo system controller was received.
(Note 2)
* *
*
Alarm/warning
The alarm No. and the warning No. that occurred is displayed. (Refer to chapter 8.
(Note 4))
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 1)
# #
b
.
(Note 3)
Test operation mode
JOG operation, positioning operation, program operation, output signal (DO) forced
output, or motor-less operation was set.
# #
d
.
# #
C
.
Note 1. The meanings of ## are listed below.
## Description
01
to
64
Axis No. 1
to
Axis No. 64
2. *** indicates the alarm No. and the warning No. "A" in the third digit indicates the A-axis, "B" indicates the B-axis, and "C"
indicates the C-axis.
3. Only a list of alarms and warnings is listed in chapter 8. Refer to "MELSERVO-J4 Servo Amplifier Instruction Manual
(Troubleshooting)" for details of alarms and warnings.
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...