5. PARAMETERS
5 - 48
5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PE01 **FCT1 Fully closed loop function selection 1
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Fully closed loop function selection
0: Always enabled
1: Switching with the control command of controller
(switching semi./full.)
0h
Switching with the control
command of controller
Control system
Off
Semi closed loop control
On
Fully closed loop control
To enable the digit, select "Fully closed loop control mode
(_ _ 1 _)" of "operation mode selection" in [Pr. PA01].
When "Absolute position detection system" is "Enabled (_ _
_ 1)" in [Pr. PA03], setting "1" will trigger [AL. 37 Parameter
error].
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PE03
*FCT2
Fully closed loop function selection 2
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Fully closed loop control error detection function selection
0: Disabled
1: Speed deviation error detection
2: Position deviation error detection
3: Speed deviation error/position deviation error detection
3h
_ _ x _
Position deviation error detection system selection
0: Continuous detection system
1: Detection system at stop (detected with command set to
"0")
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
Fully closed loop control error reset selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
0h
PE04
**FBN
Fully closed loop control - Feedback pulse electronic gear 1 - Numerator
Set a numerator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
Set the electronic gear so that the number of servo motor encoder pulses for one
servo motor revolution is converted to the resolution of the load-side encoder.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
1
1 to
65535
Each
PE05
**FBD
Fully closed loop control - Feedback pulse electronic gear 1 - Denominator
Set a denominator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
Set the electronic gear so that the number of servo motor encoder pulses for one
servo motor revolution is converted to the resolution of the load-side encoder.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
1
1 to
65535
Each
PE06
BC1
Fully closed loop control - Speed deviation error detection level
Set [AL. 42.9 Fully closed loop control error by speed deviation] of.
When the speed deviation between the servo motor encoder and load-side encoder
becomes larger than the setting value, the alarm will occur.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
400
[r/min]
1 to
50000
Each
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...