8. TROUBLESHOOTING
8 - 9
No. Name
Detail
No.
Detail name
Stop
method
(Note
2, 3)
Alarm deactivation
Process-
ing
system
(Note 8)
Stop
system
(Note 8)
Alarm
reset
CPU
reset
Cycling
the
power
Alarm
72.1 Load-side encoder data error 1
EDB
Each
axis
Each
axis
72.2
Load-side encoder data update
error
EDB
Each
axis
Each
axis
Load-side encoder
normal
communication
error 2
72.3
Load-side encoder data
waveform error
EDB
Each
axis
Each
axis
72 72.4
Load-side encoder non-signal
error
EDB
Each
axis
Each
axis
72.5
Load-side encoder hardware
error 1
EDB
Each
axis
Each
axis
72.6
Load-side encoder hardware
error 2
EDB
Each
axis
Each
axis
72.9 Load-side encoder data error 2
EDB
Each
axis
Each
axis
74.1 Option card error 1
DB
74.2 Option card error 2
DB
74
Option card error 1 74.3 Option card error 3
DB
74.4 Option card error 4
DB
74.5 Option card error 5
DB
75
Option card error 2
75.3 Option card connection error
EDB
75.4 Option card disconnected
DB
79.1
Functional safety unit power
voltage error
DB
(Note 7)
79.2
Functional safety unit internal
error
DB
79
Functional safety
unit diagnosis error
79.3
Abnormal temperature of
functional safety unit
SD
(Note 7)
79.4 Servo amplifier error
SD
79.5 Input device error
SD
79.6 Output device error
SD
79.7 Mismatched input signal error
SD
79.8 Position feedback fixing error
DB
7A
Parameter setting
error
(safety observation
function)
7A.1
Parameter verification error
(safety observation function)
DB
7A.2
Parameter setting range error
(safety observation function)
DB
7A.3
Parameter combination error
(safety observation function)
DB
7A.4
Functional safety unit
combination error (safety
observation function)
DB
7B.1
Encoder diagnosis error 1
(safety observation function)
DB
7B
Encoder diagnosis
error
(safety observation
function)
7B.2
Encoder diagnosis error 2
(safety observation function)
DB
7B.3
Encoder diagnosis error 3
(safety observation function)
DB
7B.4
Encoder diagnosis error 4
(safety observation function)
DB
7C
Functional safety
unit communication
diagnosis error
(safety observation
function)
7C.1
Functional safety unit
communication setting error
(safety observation function)
SD
(Note 7)
7C.2
Functional safety unit
communication data error
(safety observation function)
SD
(Note 7)
7D
Safety observation
error
7D.1 Stop observation error
DB
(Note 3)
7D.2 Speed observation error
DB
(Note 7)
82
Master-slave
operation error 1
82.1 Master-slave operation error 1
EDB
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...