5. PARAMETERS
5 - 24
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB06
GD2
Load to motor inertia ratio/load to motor mass ratio
Set a load to motor inertia ratio or load to motor mass ratio. Setting a value
considerably different from the actual load moment of inertia or load mass may cause
an unexpected operation such as an overshoot.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details. When the parameter
is automatic setting, the value will vary between 0.00 and 100.00.
7.00
[Multiplier]
0.00 to
300.00
Each
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Automatic
setting
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
Manual setting
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
PB07
PG1
Model loop gain
Set the response gain up to the target position.
Increasing the setting value will also increase the response level to the position
command but will be liable to generate vibration and noise.
For the vibration suppression control tuning mode, the setting range of [Pr. PB07] is
limited. Refer to section 7.1.5 (4) for details.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details.
15.0
[rad/s]
1.0 to
2000.0
Each
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Manual
setting
_ _ _ 1 (Auto tuning mode 1)
Automatic setting
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
Manual setting
_ _ _ 4 (2 gain adjustment mode 2)
PB08
PG2
Position loop gain
Set a gain of the position loop.
Set this parameter to increase the position response to level load disturbance.
Increasing the setting value will also increase the response level to the load
disturbance but will be liable to generate vibration and noise.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the following table for details.
37.0
[rad/s]
1.0 to
2000.0
Each
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Automatic
setting
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
Manual setting
_ _ _ 4 (2 gain adjustment mode 2)
Automatic setting
PB09
VG2
Speed loop gain
Set a gain of the speed loop.
Set this parameter when vibration occurs on machines of low rigidity or large
backlash. Increasing the setting value will also increase the response level but will be
liable to generate vibration and noise.
The setting of the parameter will be the automatic setting or manual setting depending
on the [Pr. PA08] setting. Refer to the table of [Pr. PB08] for details.
823
[rad/s]
20 to
65535
Each
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...