18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 13
18.2.2 Installation by DIN rail
CAUTION
To mount the servo amplifier to DIN rail, pull down the tab of hook. The hook may
come off when the tab is pushed down from the back side of the servo amplifier.
The following explains mounting and removing procedure of servo amplifier using DIN rail.
Mounting servo amplifier to DIN rail
Hook
Upper tab
Wall
DIN rail
1) Pull down the hook.
2) Hang the upper tab on the back of the servo amplifier
to the upper tab of DIN rail, and push toward to the
wall.
Hook
Upper tab
Wall
DIN rail
3) Push up the hook, and fix the servo amplifier.