5. PARAMETERS
5 - 50
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PE47 TOF Torque
offset
Set this when canceling unbalanced torque of vertical axis. Set this assuming the
rated torque of the servo motor as 100%. The torque offset does not need to be set for
a machine not generating unbalanced torque. The torque offset cannot be used for
linear servo motors and direct drive motors. Set 0.00%.
The torque offset set with this parameter will be enabled in the position control mode,
speed control mode, and torque control mode. Input commands assuming torque
offset for the torque control mode.
This parameter is supported with software version B4 or later.
0
[0.01%]
-10000
to
10000
Each
5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PF02
*FOP2 Function selection F-2
Set targets of [AL. EB The other axis error warning].
Refer to Name
and function
column.
Common
Setting
digit
Explanation
Initial
value
_ _ _ x
Target alarm selection of the other axis error warning
Select target alarms of the other axis error warning.
0: [AL. 24 Main circuit error] and [AL. 32 Overcurrent]
1: All alarms
For alarms occurring at all axes, [AL. EB The other axis
error warning] will not occur regardless of alarm No.
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PF06
*FOP5 Function selection F-5
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Electronic dynamic brake selection
0: Automatic (enabled only for specified servo motors)
2: Disabled
Refer to the following table for the specified servo motors.
0h
Series
Servo
motor
HG-KR
HG-KR053/HG-KR13/HG-KR23/HG-
KR43
HG-MR
HG-MR053/HG-MR13/HG-MR23/HG-
MR43
HG-SR
HG-SR51/HG-SR52
HG-AK
HG-AK0136/HG-AK0236/HG-AK0336
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PF12 DBT Electronic
dynamic brake operating time
Set an operating time for the electronic dynamic brake.
2000
[ms]
0
to
10000
Each
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...