5. PARAMETERS
5 - 30
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB26
*CDP
Gain switching function
Select the gain switching condition.
Set conditions to enable the gain switching values set in [Pr. PB29] to [Pr. PB36] and
[Pr. PB56] to [Pr. PB60].
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Gain switching selection
0: Disabled
1: Control command from controller is enabled
2: Command frequency
3: Droop pulses
4: Servo motor speed/linear servo motor speed
0h
_ _ x _
Gain switching condition selection
0: Gain after switching is enabled with gain switching
condition or more
1: Gain after switching is enabled with gain switching
condition or less
0h
_ x _ _
Gain switching time constant disabling condition selection
0: Switching time constant enabled
1: Switching time constant disabled
2: Return time constant disabled
Refer to section 7.2.4 for details.
This parameter is used by servo amplifier with software
version B4 or later.
0h
x _ _ _
For manufacturer setting
0h
PB27
CDL
Gain switching condition
Set a value of gain switching (command frequency, droop pulses, and servo motor
speed/linear servo motor speed) selected in [Pr. PB26].
The set value unit differs depending on the switching condition item. (Refer to section
7.2.3)
The unit "r/min" will be "mm/s" for linear servo motors.
10
[kpulse/s]
/[pulse]
/[r/min]
0 to
65535
Each
PB28
CDT
Gain switching time constant
Set the time constant until the gains switch in response to the conditions set in [Pr.
PB26] and [Pr. PB27].
1
[ms]
0 to
100
Each
PB29
GD2B
Load to motor inertia ratio/load to motor mass ratio after gain switching
Set a load to motor inertia ratio/load to motor mass ratio for when gain switching is
enabled.
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain
adjustment mode selection" in [Pr. PA08].
7.00
[Multiplier]
0.00 to
300.00
Each
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...