18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 17
24 V DC (Note 8)
Servo amplifier
U1
V1
W1
CNP1
A-axis servo motor
U
V
W
M
Motor
Encoder
CN2A
(Note 2)
Encoder
cable
(Note 2)
Encoder
cable
EM2
DICOM
Forced stop 2
CN3
(Note 4)
CALM
DOCOM
24 V DC (Note 8)
AND malfunction
(Note 3)
CN3
(Note 4)
RA1
Off
RA2
On
(Note 3)
AND malfunction
RA1
Emergency stop switch
(Note 5)
(Note 7)
Main circuit
power supply
CNP1
B-axis servo motor
U
V
W
Motor
Encoder
CN2B
(Note 5)
M
U2
V2
W2
E1
24
0
PM
CNP1
Circuit
protector
(Note 9)
RA2
(Note 6)
24 V DC
(Note 1)
48 V DC
(Note 1)
Circuit
protector
(Note 9)
24 V DC
(Note 1)
E2
RA2
24 V DC
48 V DC main circuit
power supply
24 V DC main circuit
power supply
Note 1. Use reinforced insulating type for 24 V DC and 48 V DC power supply.
2. For the encoder cable, use of the option cable is recommended. For selecting cables, refer to "Servo Motor Instruction Manual
(Vol. 3)".
3. This circuit is an example of stopping all axes when an alarm occurs. If disabling CALM (AND malfunction) output with the
parameter, configure the circuit which switches off the main circuit power supply after detection of alarm occurrence on the
controller side.
4. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.8.3.
5. For connecting servo motor power output lines, refer to "Servo Motor Instruction Manual (Vol. 3)". Connecting a wrong axis
may cause a malfunction.
6. The noiseless grounding terminals
of E1 and E2 are connected in the servo amplifier. Be sure to ground from the noiseless
grounding terminal of CNP1 to the grounding terminal
of the cabinet.
7. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
8. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
For 24 V DC power for I/O signal, use power other than 24 V DC power of servo amplifier control circuit power supply.
9. Circuit protectors are required for protection of power supplies, wires, servo amplifiers and others. When not using a circuit
protector, configure an external protective circuit such as a power supply with protection function.
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...