8. TROUBLESHOOTING
8 - 10
No. Name
Detail
No.
Detail name
Stop
method
(Note
2, 3)
Alarm deactivation
Process-
ing
system
(Note 8)
Stop
system
(Note 8)
Alarm
reset
CPU
reset
Cycling
the
power
Alarm
84
Network module
initialization error
84.1
Network module undetected
error
DB
84.2
Network module initialization
error 1
DB
84.3
Network module initialization
error 2
DB
85
Network module
error
85.1 Network module error 1
SD
85.2 Network module error 2
SD
85.3 Network module error 3
SD
86
Network
communication
error
86.1 Network communication error 1
SD
86.2 Network communication error 2
SD
86.3 Network communication error 3
SD
8A
USB communication
time-out error/
serial communication
time-out error/
Modbus RTU
communication
time-out error
8A.1
USB communication time-out
error/serial communication
time-out error
SD
Common All axes
8A.2
Modbus RTU communication
time-out error
SD
8D.1
CC-Link IE communication
error 1
SD
8D.2
CC-Link IE communication
error 2
SD
CC-Link IE
communication
error
8D.3 Master station setting error 1
DB
8D.5 Master station setting error 2
DB
8D
8D.6
CC-Link IE communication
error 3
SD
8D.7
CC-Link IE communication
error 4
SD
8D.8
CC-Link IE communication
error 5
SD
8D.9 Synchronization error 1
SD
8D.A Synchronization error 2
SD
8E.1
USB communication receive
error/serial communication
receive error
SD
Common All axes
8E.2
USB communication checksum
error/serial communication
checksum error
SD
Common All axes
8E
USB communication
error/
serial communication
error/
Modbus RTU
communication error
8E.3
USB communication character
error/serial communication
character error
SD
Common All axes
8E.4
USB communication command
error/serial communication
command error
SD
Common All axes
8E.5
USB communication data
number error/serial
communication data number
error
SD
Common All axes
8E.6
Modbus RTU communication
receive error
SD
8E.7
Modbus RTU communication
message frame error
SD
8E.8
Modbus RTU communication
CRC error
SD
88888
Watchdog
8888._
Watchdog
DB
Common All axes
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...