5. PARAMETERS
5 - 38
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PC04 **COP1 Function selection C-1
Select the encoder cable communication method selection.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
For manufacturer setting
0h
_ _ x _
0h
_ x _ _
0h
x _ _ _
Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
Incorrect setting will result in [AL. 16 Encoder initial
communication error 1]. Or [AL. 20 Encoder initial
communication error 1] will occur. Setting "1" will trigger
[AL. 37] while "Fully closed loop control mode (_ _ 1 _)" is
selected in [Pr. PA01].
For MR-J4W2-0303B6 servo amplifiers, this digit cannot be
used other than the initial value.
0h
PC05 **COP2 Function selection C-2
Set the motor-less operation, servo motor main circuit power supply, and [AL. 9B Error
excessive warning]. The motor-less operation cannot be used in the fully closed loop
control mode, linear servo motor control mode, or DD motor control mode.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Motor-less operation selection
0: Disabled
1: Enabled
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
Main circuit power supply selection
Select a voltage to be connected to the main circuit power
supply with an MR-J4W2-0303B6 servo amplifier.
0: 48 V DC
1: 24 V DC
When using 24 V DC for the main circuit power supply, set
"1" to this digit.
The setting of this digit in the J3 compatibility mode is the
same as the MR-J3W-0303BN6 servo amplifier. Set it with
[Pr. Po04]. For details, refer to "MR-J3W-0303BN6 MR-
J3W-_B Servo Amplifier Instruction Manual".
This digit is not available with MR-J4W_-_B 200 W or more
servo amplifiers.
The characteristics of the servo motor vary depending on
whether 48 V DC or 24 V DC is used. For details, refer to
"Servo Motor Instruction Manual (Vol. 3)".
0h
x _ _ _
[AL. 9B Error excessive warning] selection
0: [AL. 9B Error excessive warning] is disabled.
1: [AL. 9B Error excessive warning] is enabled.
The setting of this digit is used by servo amplifier with
software version B4 or later.
0h
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...