18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 4
Model MR-J4W2-0303B6
Environment
Ambient
temperature
Operation 0
˚
C to 55
˚
C (non-freezing)
Storage -20
˚
C to 65
˚
C (non-freezing)
Ambient
humidity
Operation
5 %RH to 90 %RH (non-condensing)
Storage
Ambience
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude
1000 m or less above sea level
Vibration resistance
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Mass [kg]
0.3
Note 1. Initial value is the 48 V DC. For 24 V DC, set [Pr. PC05] to "_ 1 _ _". The characteristics of the servo motor vary depending on
whether 48 V DC or 24 V DC is used. For details, refer to "Servo Motor Instruction Manual (Vol. 3)".
2. 0.25 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
3. This is an electronic dynamic brake. This will not operate during control circuit power supply off. In addition, It may not operate
depending on the contents of alarms and warnings. Refer to chapter 8 for details.
4. The communication cycle depends on the controller specifications and the number of axes connected.
5. When closely mounting the servo amplifiers, operate them at the ambient temperatures of 45
˚
C or lower, or the total effective
load ratio of 45 w or lower for the two axes.
6. Regenerative energy is generated when the machine, whose moment of inertia is equivalent to the permissible charging
amount, decelerates from the rated speed to stop.
7. This is moment of inertia when the motor decelerates from the rated speed to stop. This will be moment of inertia for two axes
when two motors decelerate simultaneously. And this will be moment of inertia for each axis when multiple motors do not
decelerate simultaneously.
18.1.4 Combinations of servo amplifiers and servo motors
Servo amplifier
Servo motor
MR-J4W2-0303B6
HG-AK0136
HG-AK0236
HG-AK0336
Содержание MR-J4W2-0303B6
Страница 17: ...8 App 16 Status of general purpose AC servo products for compliance with the China RoHS directive App 58 ...
Страница 39: ...2 INSTALLATION 2 8 MEMO ...
Страница 97: ...4 STARTUP 4 20 MEMO ...
Страница 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Страница 235: ...9 DIMENSIONS 9 6 MEMO ...
Страница 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Страница 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Страница 556: ...APPENDIX App 41 ...
Страница 585: ...MEMO ...