Parameter
Function assignment of external terminals
FR-E700 SC EC/ENE
6 - 137
When Pr. 495 = "0" or "10", performing a power supply reset (including a power failure) clears the REM
signal output. (The ON/OFF states of the terminals are as set in Pr. 190 to Pr. 192.) The Pr. 496 and
Pr. 497 settings are also "0".
When Pr. 495 = "1" or "11", the remote output data before power supply-off is stored into the E²PROM,
so the signal output at power recovery is the same as before power supply-off. However, it is not
stored when the inverter is reset (terminal reset, reset request through communication). (See the
chart below).
When Pr. 495 = "10" or "11", signal before rest is saved even at inverter reset.
햲
When Pr. 495 = "1," the signal condition saved in EEPROM (condition of the last power OFF) is
applied.
I001158E
Fig. 6-66:
ON/OFF example for source logic
I002128E
Fig. 6-67:
Signal condition during a reset
NOTES
The output terminal where the REM signal is not assigned using any of Pr. 190 to Pr. 192 does not
turn on/off if 0/1 is set to the terminal bit of Pr. 496 or Pr. 497. (It turns on/off with the assigned
function.)
When the inverter is reset (terminal reset, reset request through communication), Pr. 496 and
Pr. 497 values turn to "0". When Pr. 495 = "1" or "11", however, they are the settings at power off.
(The settings are stored at power off.) When Pr. 495 = "10" or "11", they are the same as before an
inverter reset is made.
Power
supply
REM
Inverter reset time
(about 1 s)
REM signal clear
REM signal held
Pr. 495 = 0, 10
Pr. 495 = 1, 11
OFF
OFF
OFF
ON
Reset
REM
Pr. 495 = 0, 1
Pr. 495 = 10, 11
Reset
REM
햲
ON
ON
ON
ON
OFF
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......