CC-Link IE Field Network Basic
Parameter
6 - 366
Reading the inverter status
The following program turns on Y00 of the output unit when station 1 inverter is running.
햲
These signals are initial values. You can change output signals using Pr. 190 to Pr. 192, Pr. 313 to
Pr. 315 "Output terminal function selection".
I003128E, I003129E
Fig. 6-177:
Program example 1
Check the data link status of the station 1
Turn on the output unit (Y00)
(0)
SM1536
SD1536.0
SD1540.0
M0
(4)
M0
X1002
Y30
(7)
END
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
b15
0
0
0
1
X
F
0
0
1
X
b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
RXF RX0
RX1F RX10
Station 1
to
Remote input
[Inverter status]
Inverter status
b0: During forward rotation
b1: Reverse running
b2: Inverter running (Terminal RUN)
b3: Up to frequency (SU signal)
b4: Overload alarm (OL signal)
b5: —
b6: Frequency detection (FU signal)
b7: Fault (Terminal ABC)
b8: —
b16: — (DO0)
b17: — (DO1)
b18: — (DO2)
to
Содержание fr-e700 series