Parameter
Frequency setting by external terminals
FR-E700 SC EC/ENE
6 - 65
JOG operation from PU
Selects Jog operation mode from the operation panel and PU (FR-PU04/FR-PU07). Operation is per-
formed only while the start button is pressed.
Fig. 6-23:
Connection example for jog operation performed
from PU
I001790E
I001791E
Fig. 6-24:
JOG operation performed from PU
Power
supply
Motor
Inverter
Operation panel
햲
Confirmation of the RUN indication and operation
mode indication.
The monitor mode must have been selected.
The inverter must be at a stop.
햳
Press the PU/EXT key to choose the
PU JOG operation mode.
햴
Press the RUN key.
The motor rotates while the key is pressed.
It rotates at 5 Hz (initial value of Pr. 15).
햵
Release the RUN key to stop the motor.
When changing the frequency of PU JOG operation:
햶
Press the MODE key to choose the parameter
setting mode.
햷
Turn the digital dial until Pr. 15 "JOG frequency"
appears.
햸
Press the SET key to show the currently set value
(5 Hz).
햹
Turn the digital dial to set the value to "10.00"
(10.00 Hz).
햺
Press the SET key to set.
햻
Perform the operations in steps
햲
to
햵
The motor rotates at 10 Hz.
Hold down
Stop
Operation
Display
Release
The parameter number read previously
appears.
Flicker ... Parameter setting complete!
"PRM" indication is lit.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......