Operation
Operation panel
FR-E700 SC EC/ENE
4 - 11
4.3.3
Easy operation mode setting (easy setting mode)
A frequency inverter can be controlled alone via the control unit, through external signals (switch, SPC
outputs, external setpoint sources, etc.) or through a combination of external signals and inputs to
the control unit. The choice of operation mode is done by setting parameter 79. (Refer to section
5.1.6.)
Setting of Pr. 79 "Operation mode selection" according to combination of the start command and
speed command can be easily made.
In the following example the parameter is set to the value "3" so that the motor is started by signals
to the STF and STR terminals and the speed can be adjusted using the digital dial on the operator
device.
I001737E, I001738E
Fig. 4-8:
One can immediately change parameter 79 by simultaneously pressing the PU/EXT
and MODE buttons.
NOTES
If MODE is pressed before pressing SET, the easy setting mode is terminated and the display goes
back to the monitor display.
If the easy setting mode is terminated while Pr. 79 = "0" (initial setting), the operation mode
switches between the PU operation mode and the External operation mode. Check the operation
mode.
Reset can be made with STOP/RESET.
햲
Screen at powering ON
The monitor display appears.
햳
Press PU/EXT and MODE for 0.5 s.
햴
Turn the digital dial, until "3" appears.
(Refer to the table on the next page for
other settings.)
햵
Press SET to set.
Operation
Display
Flickering
Flickering
Flickering
Flicker ... Parameter setting complete!
The monitor display appears after 3s.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......