PU operation mode
Basic settings
5 - 26
5.2.4
Perform frequency setting by analog voltage input
In this type of setpoint selection a potentiometer is connected to the frequency inverter. The poten-
tiometer is supplied with a voltage of 5 V through terminal 10 of the frequency inverter.
●
Pr. 79 "Operation mode selection" must be set to "4" (external/PU combined operation mode 2).
●
Use the RUN key to give a start command.
I001772E
Fig. 5-17:
Frequency setting by analog voltage input
Power supply
Motor
Inverter
Frequency setting
potentiometer
(1 k /2 W)