Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 17
햲
These parameters are communication parameters that are not cleared when parameter clear (all
clear) is executed from RS-485 communication.
(Refer to section 6.19 for RS-485 communication).
햳
This setting is only available for the FR-E700 SC ENE.
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Communica
tion initial setting
124
PU communication
CR/LF presence/absence
selection
1
1
0
Without CR/LF
✔
✔
햲
✔
햲
1
With CR
2
With CR/LF
342
Communication E²PROM write
selection
1
0
0
Parameter values written by communication
are written to the E²PROM and RAM.
✔
✔
✔
1
Parameter values written by communication
are written to the RAM.
343
Communication error count
1
0
Read only
Display the number of communication errors
during Modbus®-RTU communication. Read
only.
Displayed only when Modbus®-RTU protocol
is selected.
—
—
—
349
햳
Communication reset
selection
1
0
0, 1
In the External operation mode or the PU
operation mode, use this parameter to
disable an error reset command sent
through the Ethernet network (CC-Link IE
Field Network Basic).
✔
✔
✔
501
햳
Communication error
occurrence count display
1
0
0
Displays the communication error
occurrence count.
✔
✔
✔
502
Stop mode selection at
communication error
1
0
0/3
You can select the
inverter operation
if a
communication
error occurs.
Coasts to stop
✔
✔
✔
1/2
Decelerates to stop
549
Protocol selection
1
0
0
Mitsubishi
inverter
(computer link)
protocol)
After setting change,
reset (switch power off,
then on) the inverter.
The setting change is
reflected after a reset.
✔
✔
햲
✔
햲
1
Modbus®-RTU
protocol
Tab. 6-1:
Parameter overview (17)
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......