Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 25
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
St
op
-on c
on
tac
t c
on
tr
ol
270
Stop-on contact
control selection
1
0
0
Without stop-on contact control
✔
✔
✔
1
Stop-on contact control
275
Stop-on contact
excitation current
low-speed multiplying factor
0.1%
9999
0–300%
Usually set a value between 130% and
180%.
Set the force (holding torque) for stop-on
contact control.
✔
✔
✔
9999
No compensation.
276
PWM carrier
frequency at stop-on contact
1
9999
0–9
Set a PWM carrier frequency for stop-on
contact control.
(Valid at the output frequency of 3 Hz or
less.)
✔
✔
✔
9999
As set in Pr. 72 "PWM frequency selection".
—
277
Refer to Pr. 22
Br
ak
e sequenc
e func
tion
278
Brake opening frequency
0.01 Hz
3 Hz
0–30 Hz
Set to the rated slip frequency of the motor
+ about 1.0 Hz.
This parameter may be set only if Pr. 278
Pr. 282.
✔
✔
✔
279
Brake opening current
0.1%
130%
0–200%
Generally, set this parameter to about 50 to
90%. If the setting is too low, the load is
liable to drop due to gravity at start.
Suppose that the rated inverter current is
100%.
✔
✔
✔
280
Brake opening current
detection time
0.1 s
0.3 s
0–2 s
Generally, set this parameter to about 0.1 to
0.3s.
✔
✔
✔
281
Brake operation time at start
0.1 s
0.3 s
0–5 s
Pr. 292 = 7: Set the mechanical delay time
until the brake is loosened.
Pr. 292 = 8: Set the mechanical delay time
until the brake is lo about 0.1 to
0.2 s.
✔
✔
✔
282
Brake operation frequency
0.01 Hz
6 Hz
0–30 Hz
At this frequency, the brake opening request
signal (BOF) is switched off. Generally, set
this parameter to the Pr. 278 s 3 to
4 Hz.This parameter may be set only if Pr.
278
Pr. 282.
✔
✔
✔
283
Brake operation time at stop
0.1 s
0.3 s
0–5 s
Pr. 292 = 7: Set the mechanical delay time
until the brake is 0.1 s.
Pr. 292 = 8: Set the mechanical delay time
until the brake is about 0.2 to 0.3
seconds.
✔
✔
✔
292
Automatic acceleration/
deceleration
1
0
0/1/7/8/11
Brake sequence function is made valid when a setting is "7 or 8".
Dr
oop c
on
tr
ol
286
Droop gain
0.1%
0%
0
Droop control is invalid
✔
✔
✔
0.1–100%
Set the drooping amount at the rated torque
as a percentage with respect to the rated
motor frequency.
287
Droop filter time constant
0.01 s
0.3 s
0–1 s
Set the time constant of the primary delay
filter applied to the torque current.
✔
✔
✔
Tab. 6-1:
Parameter overview (25)
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC
AD
MFVC
AD
MFVC
AD
MFVC
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......