Simple mode parameter list
Basic settings
5 - 14
Selection method of general-purpose magnetic flux vector control
Fig. 5-10:
Selection method of general-purpose magnetic flux vector control
Perform secure wiring.
(Refer to section 3.2.)
Set the motor. (Pr. 71) (Refer to page 5-12.)
햲
For other settings of Pr. 71, refer to section 6.8.2.
햳
Refer to section 5.1.8 for offline auto tuning.
Motor
Pr. 71
햲
Remarks
Mitsubishi
Standard motor,
high efficiency
motor
SF-JR
0
Initial value
SF-HR
40
—
Others
3
Offline auto tuning is necessary.
햳
Constant-torque
motor
SF-JRCA 4P
1
—
SF-HRCA 4P
50
—
Others (SF-JRC, etc.)
13
Offline auto tuning is necessary.
햳
Other
manufac-
turer's
Standard motor
—
3
Offline auto tuning is necessary.
햳
Constant-torque
motor
—
13
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 5-12.)
Set the operation command. (Refer to section 5.2.)
Test run
Set motor capacity (kW) in Pr. 80 "Motor capacity" and the number of motor
poles (number of poles) in Pr. 81 "Number of motor poles". (V/F control is
performed when the setting is "9999" (initial value).
Select the start command and speed command.
1) Start command
–
Operation panel: Setting by pressing the RUN key of the
operation panel
–
External command: Setting by forward rotation or reverse
rotation command (terminal STF or STR)
2) Speed command
–
Operation panel: Setting by pressing the digital dial of the
operation panel
–
External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to
terminal 2 (or terminal 4).
–
Multi-speed command:
The external signals (RH, RM, RL) may also be used to give
speed command.
앫
Perform offline auto tuning. (Pr. 96) (Refer to section 5.1.8.)
앫
Set slip compensation. (Pr. 245, Pr. 246, Pr. 247, refer to section 6.3.4).
Select the control method. (Pr. 800)
(Refer to page 5-12.)
Set "30" in Pr. 800 to make general-purpose magnetic flux vector control
valid.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......