Parameter
Selection and protection of a motor
FR-E700 SC EC/ENE
6 - 87
6.8.2
Applied motor (Pr. 71, Pr. 450)
Setting of the used motor selects the thermal characteristic appropriate for the motor. Setting is re-
quired to use a constant-torque motor. Thermal characteristic of the electronic thermal relay function
suitable for the motor is set.
When general-purpose magnetic flux vector or advanced magnetic flux vector control is selected, the
motor constants (SF-JR, SF-HR, SF-JRCA, SF-HRCA, etc.) necessary for control are selected as well.
Pr. No. Name
Initial Value
Setting Range
Description
Parameters referred to
Refer to
Section
71
Applied motor
0
0/1–3–6/
13–16/23/24/40/
43/44/50/53/54
Selecting the standard motor or
constant-torque motor sets the
corresponding motor thermal
characteristic.
0
12
80
81
82–84
90–94
96
800
Torque boost
DC injection brake
operation voltage
Motor capacity
Number of motor poles
Motor constants
Control method
selection
450
Second applied motor
9999
0/1
Set when using the second motor.
9999
Second motor is invalid
(thermal characteristic of the first motor
(Pr. 71))