Parameter
Selection of operation mode and operation location
FR-E700 SC EC/ENE
6 - 209
Operation mode selection flow
In the following flowchart, select the basic parameter setting and terminal connection related to the
operation mode:
START
Connection
Parameter Setting
Operation
Where is the start command source?
From external (STF/STR terminal)
Where is the frequency set?
From external (Terminal 2, 4, JOG,
multi-speed, etc.)
STF (forward rotation)/
STR (reverse rotation)
(Refer to page 6-116)
Terminal 2, 4-5 (analog),
RL, RM, RH, JOG, etc.
Frequency setting signal ON
STF(STR) ON
From PU
STF (forward rotation)/
STR (reverse rotation)
(Refer to page 6-116)
Pr. 79 = 3
(External/PU combined
operation 1)
Digital dial
From communication (PU connector/communication option)
PU connector or
communication option?
PU connector
(RS-485 communication)
STF (forward rotation)/
STR(reverse rotation)
(Refer to page 6-116)
Pr. 338 = 1
Pr. 340 = 1
Communication frequency setting
command sending
STF(STR) ON
Communication option
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Pr. 338 = 1
Pr. 340 = 1
Communication frequency setting
command sending
STF(STR) ON
From PU
Where is the frequency set?
From external (Terminal 2, 4, JOG,
multi-speed, etc.)
Terminal 2, 4-5 (analog),
RL, RM, RH, JOG, etc.
Pr. 79 = 4
(External/PU combined
operation 2)
Frequency setting terminal ON
RUN/FWD/REV key ON
From PU
Pr. 79 = 1
(Fixed to PU operation)
Digital dial
From communication (PU connec-
tor/communication option)
From communication (PU connector/communication option)
PU connector or
communication option?
PU connector
(RS-485 communication)
Where is the frequency set?
From external (Terminal 2, 4, JOG, multi-speed, etc.)
Terminal 2, 4-5 (analog),
RL, RM, RH, JOG, etc.
Pr. 339 = 1
Pr. 340 = 1
Frequency setting terminal ON
Communication start command
sending
From the operation panel
From communication (PU connector)
Pr. 340 = 1
Communication frequency setting
command sending
Communication start command
sending
Communication option
Where is the frequency set?
From external (Terminal 2, 4, JOG, multi-speed, etc.)
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Terminal 2, 4-5 (analog), RL, RM, RH,
JOG-PC, etc.
Pr. 339 = 1
Pr. 340 = 1
Frequency setting terminal ON
Communication start command
sending
From the operation panel
From communication (communication option)
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Pr. 340 = 1
Communication frequency setting
command sending
Communication start command
sending
Disabled
Disabled
Disabled
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......