Parameter
Selection of operation mode and operation location
FR-E700 SC EC/ENE
6 - 227
Explanation of table:
External:
Operation is valid only from external terminal signal.
NET:
Control only from communication is valid.
Combined:
Operation is valid from either of external terminal and communication.
—:
Operation is invalid from either of external terminal and communication.
Operation
Location
Selection
Communication Operation Command
Source (Pr. 338)
0: NET
1: External
Remarks
Communication Speed Command
Source (Pr. 339)
0: NET
1:
External
2:
External
0: NET
1:
External
2:
External
S
elec
tiv
e func
tion
P
r. 178 t
o P
r. 184 setting
24
MRS
Output stop
Combined
External
Pr. 79
7
PU operation interlock
External
Pr. 79 = 7
(When X12 signal is
not assigned)
25
STOP Start self-holding selection
—
External
60
STF
Forward rotation command
NET
External
61
STR
Reverse rotation command
NET
External
62
RES
Reset
External
65
X65
PU-NET operation switchover
External
66
X66
External-NET operation
switchover
External
67
X67
Command source switchover
External
Tab. 6-64:
Writing operation and speed commands (2)
NOTES
The control source of communication is as set in Pr. 550 and Pr. 551.
The Pr. 338 and Pr. 339 settings can be changed while the inverter is running when Pr. 77 = "2".
Note that the setting change is reflected after the inverter has stopped. Until the inverter has
stopped, communication operation command source and communication speed command
source before the setting change are valid.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......